Use and Care Manual

2
PERFORMANCE
Model HP
GPH of Water @ Total Feet Of Lift
Max.
Lift
0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft.
33011-3 1/4 3450 3200 2800 2100 1500 200 26 ft.
33021-3 1/3 3600 3400 3000 2500 1900 1000 28 ft.
33031-3 1/2 4100 3800 3500 2900 2300 1600 29 ft.
32011-3/32011-1 1/3 3800 3400 3000 2500 1800 25 ft.
32021-3/32021-1 1/2 4300 3900 3500 3100 2500 1700 30 ft.
32031-3/32031-1 1/2 3900 3700 3400 3100 2700 2200 37 ft.
30011-3 1/2 4600 4320 3840 3060 1800 22 ft.
30021-3 3/4 5150 4800 4320 3660 2580 25 ft.
30031-3 1 5500 5160 4680 4200 3480 2340 30 ft.
SAFETY INSTRUCTIONS
1. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an
explosion or fire, resulting in property damage, serious personal injury, and/or death.
2. ALWAYS disconnect the power to the pump before servicing.
3. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do
not disassemble the motor housing.
4. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in
water before disconnect the power.
5. Release all pressure and drain all water from the system before servicing any component.
6. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life
threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use
of an extension cord to power this pump is not permitted.
8. Wear safety goggles at all times when working with pumps.
9. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved
3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The
3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type
receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly
grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and
local codes and ordinances. All wiring should be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not
use damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING
TO USE ADAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.