CAUTION
IMPORTANT NOTES
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• InstallationandUseMUST comply with all state and local plumbing codes.
• Protect from freezing.Drainlterwhentemperaturesdropbelow40°F(4.4°C).
• Do notinstallifwaterpressureexceeds125psi(862kPa).Ifyourwaterpressureexceeds125psi,you
mustinstallapressurelimitingvalve.Contactaplumbingprofessionalifyouareuncertainhowtocheck
your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a
waterhammerarrester.Contactaplumbingprofessionalifyouareuncertainhowtocheckforthiscondition.
• Thesystemmust be installed on COLDwaterlinesonly,maximumtemperatureis100°F(37.8°C).
•Thesystemmustbeinstalledwiththeinletandoutletportsaslabeled.Makesurenottoreverseconnections.
Thedisposableltercartridgemust be replaced every six months or at the specified service cycle.
• Do not use a torch or other high temperature sources near filter or plastic fittings.
• Do not install in direct sunlight.
• Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount
the bracket.
• Mountlterinsuchapositionastopreventitfrombeingstruckbyotheritemsusedintheareaofinstallation
(wastebaskets,etc).
• Onplasticttings,neverusepipesealantorpipedope.Usethreadsealingtapeonly.
• Ensure all tubing and fittings are secure and free of leaks.
• Do notinstallunitifcolletismissing.ContactCUNOifcolletsaremissingfromanyttings.
•SHUT OFF FUEL SUPPLY TO WATER HEATER after water is shut off.
• Shutoffinletwatersupplyanddepressurizesystemasshowninmanualwhenchangingcartridgesorservicing.
•Failuretofollowinstructionsmayvoidwarranty.
•Allowaminimumof71/2”(19.5cm)clearspaceunderltertofacilitatecartridgechange.
• Donotcrimpcoppertubing.
Somestateandlocalplumbingcodesmayprohibittheuseofsaddle-typevalvesand/ordrainconnections.
Theuseofsaddle-typevalvesareprohibitedin:Alaska,Delaware,Idaho,Kentucky,Massachusetts,Michi-
gan,Minnesota,NewHampshire,NorthDakota,Ohio,OreganandSouthDakota.Checkyourlocalplumb-
ing codes for any restrictions that apply.
•Itismandatorythatsafetyglassesbewornduringsinkholedrillingoperationstopreventeyeinjury.
2 3
Introduction
This manual explains installation and operation of the Aqua-Pure
®
AP-RO5500ReverseOsmosis(RO) Drinking
Water Filtration System. Please read each section of this manual carefully.
The Aqua-Pure AP-RO5500 RO Drinking Water Filtration System is designed to connect permanently to a home
plumbing system. To ensure that the installation conforms to your state and local plumbing codes, it is recommended
that the installation be performed by a qualified installation specialist for RO drinking water filtration systems or a
licensed plumber.
The RO module is shipped with a preservative solution. Make sure that you flush the system thorough-
ly as directed before the first use.
NOTE:MakesurethattheOwnersWarrantyRecordCardislledoutandmailedwithin10daysofinstallation.
Installation Checklist and Table of Contents
1. DetermineSystemLocation ..................................................................................................................... 4
2. PreparetheAreaforInstallation ............................................................................................................... 4
3. Prepare the Filtration System for Installation ............................................................................................ 4
4. InstalltheFeedWaterValveandTubing ................................................................................................... 5
5. Prefill and Sanitize the Storage Tank ........................................................................................................ 5
6. InstalltheDrainConnection...................................................................................................................... 6
7. InstalltheFaucet ...................................................................................................................................... 6
8. MaketheFaucetMountingHole ............................................................................................................... 7
9. MounttheFaucet ...................................................................................................................................... 8
10. MakeInitialFaucetTubingConnections ................................................................................................... 8
11. InstallthePuricationAssemblyandStorageTank .................................................................................. 9
12. MakeFinalTubingConnections ................................................................................................................ 9
13. InstallIcemakerHookup(optional) ......................................................................................................... 10
14. InstallFilterCartridges ........................................................................................................................... 10
15. StartUptheSystem ............................................................................................................................... 10
16. InstallationTroubleshooting .................................................................................................................... 11
17. Maintenance ........................................................................................................................................... 12
18. PartsList ................................................................................................................................................. 14
19. InstallationDiagrams(Figures1-6) ......................................................................................................... 15
20. LimitedOneYearWarranty ..................................................................................................................... 18
• Failuretofollowinstructionsmayvoidwarranty.
IMPORTANT NOTES