Use and Care Manual

NSF/ANSI 42
Minimum
reduction
Overall %
Reduction
Results
Chlorine Reduction,
Free Available
<0.5 mg/l 97.66% Pass
Chloramine Reduction,
Free Available
<0.5 mg/l 97.66% Pass
Particulate Reduction 85% 99.9% Pass
NSF/ANSI 53
Reduction
requirement
Overall %
Reduction
Results
Cyst Live Cryptosporidium
& Giardia
99.95% >99.99% Pass
Mercury Reduction pH 8.5 <2 ug/L >95.8% Pass
Mercury Reduction pH 6.5 <2 ug/L >96.5% Pass
Lead Reduction pH 6.5 <10 ug/L >99.4% Pass
Lead Reduction pH 8.5 <10 ug/L >99.3% Pass
MTBE Reduction <5 ug/L 86.6% Pass
Turbidity <0.5 NTU 99.1% Pass
VOC Surrogate Test 95% 99.4% Pass
Asbestos Reduction 99% >99% Pass
Organic chemicals included by surrogate testing
VOCs
(by surrogate testing using chloroform)
Drinking water regulatory
level (MCL/MAC) mg/L
Influent/Unfiltered Euent/Filtered Percent Reduction
alachlor 0.002 0.050 0.001 >98%
atrazine 0.003 0.100 0.003 >97%
benzene 0.005 0.081 0.001 >99%
carbofuran 0.04 0.190 0.001 >99%
carbon tetrachloride 0.005 0.078 0.0018 98%
chlorobenzene 0.1 0.077 0.001 >99%
chloropicrin 0.015 0.0002 99%
2,4-D 0.07 0.110 0.0017 98%
dibromochloropropane (DBCP) 0.0002 0.052 0.00002 >99%
o-dichlorobenzene 0.6 0.080 0.001 >99%
p-dichlorobenzene 0.075 0.040 0.001 >98%
1,2-dichloroethane 0.005 0.088 0.0048 95%
1,1-dichloroethylene 0.007 0.083 0.001 >99%
cis-1,2-dichloroethylene 0.07 0.170 0.0005 >99%
trans-1,2-dichloroethylene 0.1 0.086 0.001 >99%
1,2-dichloropropane 0.005 0.080 0.001 >99%
cis-1,3-dichloropropylene 0.079 0.001 >99%
dinoseb 0.007 0.170 0.0002 99%
endrin 0.002 0.053 0.00059 99%
ethylbenzene 0.7 0.088 0.001 >99%
ethylene dibromide (EDB) 0.00005 0.044 0.00002 >99%
haloacetonitriles (HAN)
Bromochloroacetontrile 0.022 0.0005 98%
Dibromoacetontrile 0.024 0.0006 98%
Dichloroacetontrile 0.0096 0.0002 98%
Trichloroacetontrile 0.015 0.0003 98%
haloketones (HK)
1,1-dichloro-2-propanone 0.0072 0.0001 99%
1,1,1-trichloro-2-propanone 0.0082 0.0003 96%
heptachlor (H-34, Heptox) 0.0004 0.025 0.00001 >99%
heptachlor epoxide 0.0002 0.0107 0.0002 98%
hexachlorobutadiene 0.044 0.001 >98%
hexachlorocyclopentadiene 0.05 0.060 0.000002 >99%
lindane 0.0002 0.055 0.00001 >99%
methoxychlor 0.04 0.050 0.0001 >99%
pentachlorophenol 0.001 0.096 0.001 >99%
simazine 0.004 0.120 0.004 >97%
styrene 0.1 0.150 0.0005 >99%
1,1,2,2-tetrachloroethane 0.081 0.001 >99%
tetrachloroethylene 0.005 0.081 0.001 >99%
toluene 1 0.078 0.001 >99%
2,4,5-TP (silvex) 0.05 0.270 0.0016 99%
tribromoacetic acid 0.042 0.001 >98%
1,2,4-trichlorobenzene 0.07 0.160 0.0005 >99%
1,1,1-trichloroethane 0.2 0.084 0.0046 95%
1,1,2-trichloroethane 0.005 0.150 0.0005 >99%
trichloroethylene 0.005 0.180 0.0010 >99%
Trihalomethanes (THMs) Influent/Unfiltered Euent/Filtered Percent Reduction
Bromodichloromethane (THM)
0.080 0.300 0.015 95%
Bromoform (THM)
Chloroform (THM)
Chlorodibromomethane (THM)
Xylenes (total) 10 0.070 0.001 >99%
This system’s ability to maintain healthy minerals and reduce
pharmaceuticals has also been tested.
Healthy Minerals Results
Calcium* Tested to maintain levels
Potassium* Tested to maintain levels
Magnesium* Tested to maintain levels
Pharmaceutical Amount Reduced
5,5-Diphenylhydantion* 87.6%
Ibuprofen* >99%
Acetaminophen* >99%
Caeine* >99%
Carbamazipine* >99%
Trimethoprim* 95.7%
Estrone* >99%
Prednisone* >99%
Progesterone* >99%
*Not part of NSF/ANSI Certification
Testing was performed under standard laboratory conditions,
actual performance may vary. Filter usage must comply with
all state and local laws.
Filter is only to be used with cold water. Systems certified
for cyst reduction may be used on disinfected waters that
may contain filterable cysts. See owner’s manual for general
installation conditions and needs as well as manufacturer’s
limited warranty.
Do not use with water that is microbiologically unsafe or
of unknown water quality without adequate disinfection
before or after the system.
Testing Performed under NSF/ANSI Standards 42 and 53 and in accordance with the California Department of Health Services Drinking Water Treatment Device Program. This system
has been tested according to NSF/ANSI 42 & 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 & 53.
System tested and certified by NSF
International against NSF/ANSI Standard
42 and 53 for the reduction of the claims
specified on the Performance Data Sheet
and at www.nsf.org.
Performance Data for the Aquasana Under Counter Water Filter
Model Replacement Operating pressure range Rated capacity Operating temp range Rated flow
AQ-5200 AQ-5200R 20-80 psi (1.40-5.624 kg/cm
2
) 500 gallons 40-90° F (4.44-32.2° C) 0.5 gpm
Manufactured by: Aquasana, Inc. - 6310 Midway Road - Haltom City, Texas 76117 - 866-662-6885
aq5200_PDS_20130215