Specification

NSF/ANSI 42
Influent Challenge
Chlorine
Pressure
drop
Minimum
reduction
Overall %
reduction
Results
Chlorine Reduction, Free Available 2.02 mg/L ±10% 10.5 psi ≥50% >97.4% Pass
Sample
Point
Accumulated
Volume (gal)
Dynamic Pressure
(psi)
Chlorine, Free Available (mg/L) % Reduction of
this sample
Influent Euent
Startup 10 60 2.04 ND (<0.01) 99.51%
6% 60,000 60 2.09 ND (<0.01) 99.52%
12% 120,000 60 2.09 ND (<0.01) 99.52%
18% 180,000 60 2.07 ND (<0.01) 99.52%
24% 240,000 60 1.93 ND (<0.01) 99.52%
30% 300,000 60 1.91 ND (<0.01) 99.52%
36% 360,000 60 2.02 ND (<0.01) 99.48%
42% 420,000 60 1.82 ND (<0.01) 99.45%
48% 480,000 60 1.89 ND (<0.01) 99.47%
50% 500,000 60 2.00 ND (0.02) 99.00%
54% 540,000 60 1.95 0.09 97.73%
60% 600,000 60 2.07 0.05 97.58%
66% 660,000 60 1.84 0.08 95.65%
72% 720,000 60 1.84 0.08 99.54%
78% 780,000 60 1.93 0.06 96.89%
84% 840,000 60 2.19 ND (<0.02) 98.62%
90% 900,000 60 2.08 0.06 97.12%
96% 960,000 60 2.11 0.15 91.94%
100% 1,000,000 60 2.09 0.15 92.82%
Independent testing was
performed under standard
laboratory conditions, actual
performance may vary. All
data reported is associated
with quality control that met method, EPA, NSF/ANSI or
internal laboratory specification.
Filter is only to be used with cold water. Systems certified for
cyst reduction may be used on disinfected waters that may
contain filterable cysts.
See owner’s manual for general installation conditions and
needs as well as manufacturer’s limited warranty.
Not all contaminants listed may be present in your water.
Filter does not remove all contaminants that may be present
in tap water.
Do not use with water that is microbiologically unsafe or
of unknown water quality without adequate disinfection
before or after the system.
Aquasana, Inc.
6310 Midway Road
Haltom City, Texas 76117
866-662-6885
www.aquasana.com
This system has been tested according to NSF/ANSI 42 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42.
Performance data for the Aquasana whole water filter systems
Models Replacement Max operating
pressure
Rated
capacity
Operating
temp range
Rated
flow
EQ-1000 EQ-1000R 100 psi 1,000,000 gallons 40-90° F 7.0 gpm