Installation Guide

9
CARE AND MAINTENANCE
TROUBLESHOOTING
Clean periodically with a soft cloth. Avoid abrasive cleaners, steel wool and harsh chemicals as
thesewilldullthenishandvoidyourwarranty.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Leak from under handle. Retainer nut has come loose.
O-ring on cartridge is dirty or
damaged.
Tighten the retainer nut. Clean
or replace O-ring.
Aerator has an inconsistent
waterowpattern.
Aeratorisdirtyormistted. Remove aerator, check for
debris in the aerator screens,
andconrmtherubberwasher
is properly installed.
Water leaks from aerator Cartridge needs to be replaced. Remove handle assembly, trim
cap and locking nut. Take out
existingcartridgeanddiscard.
Replace with new cartridge and
reassemble.
Low water pressure Quick connector is clogged with
debris.
Turn off water supply and
disconnect the quick
connector from the discharge
tube. Unscrew the quick
connector from the hose and
clean under running water.
Screw back onto hose and
connect back to discharge tube.
Testwaterow.Ifwater
pressure is still low then replace
the quick connector.