Installation manual

AQUAERO 5
After assigning a controller to an output
outputoutput
output and configuring output specific
parameters like minimum power or start boost, the signal chain from sensor
via controller to output is completely configured.
5.1. Sensors
5.1. Sensors5.1. Sensors
5.1. Sensors
The following sensors are available:
Temperature sensors
Virtual sensors: Can be used to determine maximum, average or
minimum value of up to three temperature sensors.
Software sensors: These values can be written into the device using the
aquasuite software. They can for example be used to transmit the
current CPU temperature to the aquaero 5 and use this value for
controlling fan speeds.
Flow sensors
Power measurement: Allow calculating power dissipation from a
temperature difference and corresponding flow rate.
5.2. Controllers
5.2. Controllers5.2. Controllers
5.2. Controllers
The following controller models are available:
Curve controllers: Adjustable control curves, defined by 16 temperature
values and corresponding output values.
Target value controllers: Automatic output adjustment to match a
predefined target temperature.
Two point controllers: Simple on/off controller, using a lower and upper
temperature limit.
Preset values: Constant preset values.
RGB LED controller: Temperature-dependent color gradient controller
for the RGB LED output.
5.3. Outputs
5.3. Outputs5.3. Outputs
5.3. Outputs
The following outputs are available:
Fans
Power outputs
LED outputs
© 2011 Aqua Computer GmbH & Co. KG - 10 -