Instructions / Assembly

IMPORTANT! The following conditions for the feed water supply must be met or warranty will
be void and manufacturer assumes no responsibility for damage to system or property.
1. Water Temperature Parameters
Maximum: 105º F (40.6º C)
Minimum: 33º F (0.55º C)
WARNING: Do not allow the system to freeze, the lter always contains water and will be
destroyed if frozen. Do not plumb system to hot water, The tubing will expand or burst, and
lter will be destroyed which will void warranty and manufacturer’s responsibility.
2. Water Pressure Parameters
Maximum: 75 PSI (5.27 kg/cm2)
Minimum: 25psi (1.76 kg/cm2)
WARNING: This system is designed to operate at a water pressure in the range of 25 PSI to 75
PSI (1.76 kg/cm2 to 5.27 kg/cm2). Operating at a pressure lower than the minimum required PSI
will result in lower quality and quantity of product water. Operating at a pressure higher than
the maximum allowed PSI will cause severe damage to the system.
WARNING: Do not proceed with the installation until water pressure is conrmed to be lower
than 75 psi. A pressure regulator must be installed on the feed water source coming into the
home to reduce water pressure going into the system and ensuring water pressure does not
exceeds 75 psi.
3. Water Condition Parameters
Turbidity: <5 NTU
pH: 4 - 11
Hardness: < 7 grains per gallon (< 120 ppm)
Sulde, Iron Manganese: < 0.01 ppm
Chlorine: < 2 ppm
Total Dissolved Solids (TDS): < 1,000 ppm
4. Pre-install environment checklist
Installation needs to comply with state and local laws and regulations.
System must be installed indoor away from possible environmental damage
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. Systems certied for cyst reduc-
tion may be used on disinfected water that may contain lterable cysts.
The system is best installed under the kitchen sink. But if that is not feasible, you can
install the system anywhere where there is a cold water supply with sufcient water
pressure.
System Operation Parameters and
Installation checklist
3