Installation Guide

8
AQUASURE FORTITUDE PRO SERIES
STEP 4. Attaching the Water Supply Pipe to the Pre-Filter
1. Wrap the 1” male threaded ttings that will be used to connect the
plumbing to the pre-lter with ve (5) to six (6) wraps of Teon tape.
2. Attach the 1” male threaded tting from the incoming water supply
plumbing to the IN port and OUT port of the pre-lter system.
Note: Use the 1” to 3/4” inch male adapter for 3/4” plumbing
STEP 5. Installing the Pre-Filter Cartridge
1. Unwrapp the lter cartridge and place it inside the
housing. Make sure the lter is centered on the stand
pipe located inside the housing at the base.
2. Screw on the housing with the lter inside and
screw onto the corresponding head by turning it
counterclockwise using the supplied housing wrench.
Note: Make sure the o-ring is inside the housing
and do not over tightening the housing.
STEP 3. Mounting the Pre-Filter
1. Position the system on the wall at the desired mounting
location with minimum of six (6) inches of ground clearance
from the oor to the base of the system.
2. Using a pen or pencil and mark the mounting hole on the
back of the bracket onto the wall.
Note: Please make sure the bracket mount is leveled using
a leveling tool to ensure evenly distributed stress on the
bracket. Make sure the mounting point is position on a stud
to properly secure the bracket.
3. Mount the system onto the wall using the provided Lag Bolts
and Washers.