Installation Guide

12
AQUASURE FORTITUDE PRO SERIES
Process Descripon Recommended Time
FILTER
This is the standard setting when your water
treatment system is in use.
Water will ow in from the source and out to
your home plumbing.
Ongoing
BACKWASH
The Backwash setting is used to remove
impurities from the system and expands the
media.
Water will ow out of the valve port that
should be sent to the drain.
Recommend every 7-10
days or as needed.
Run water for 15 minutes.
Then perform a Fast Rinse
cycle.
More time may be needed
if desired result is not
achieved.
FAST RINSE
Fast Rinse setting is used immediately after
the Backwash cycle. The Fast Rinse process
forces the media to settle back down into the
tank.
Water will ow out of the valve port that
should be sent to the drain.
Perform immediately after
the Backwash cycle.
Run water for 5 minutes.
In from the main
water line
Out to the
house
OUT TO DRAIN
B
A
C
K
W
A
S
H
F
A
S
T
R
I
N
S
E
F
I
L
T
E
R
GETTING TO KNOW THE VALVE HEAD
IMPORTANT! The valve head has three settings. By reviewing the information below you can
ensure the system is working properly and providing you with improved water quality.