Aquatec 5800 Series Data Sheet

PERFORMANCE DATA
DISCHARGE
PUMPHEAD MODEL
PRESSURE 58X0 58X1 58X2 58X3 58X4
(PSI)
FLOW
(GPM)
CURRENT
(AMPS)
FLOW
(GPM)
CURRENT
(AMPS)
FLOW
(GPM)
CURRENT
(AMPS)
FLOW
(GPM)
CURRENT
(AMPS)
FLOW
(GPM)
CURRENT
(AMPS)
70
0.50 2.60 0.60 3.30 0.86 4.20 0.98 5.00 1.10 5.60
60
0.52 2.50 0.65 3.10 0.90 3.80 1.00 4.50 1.15 5.10
50
0.56 2.20 0.70 2.80 0.94 3.50 1.05 4.00 1.20 4.60
40
0.60 2.00 0.75 2.50 0.96 3.00 1.10 3.50 1.25 4.00
30
0.65 1.80 0.80 2.10 0.98 2.60 1.15 3.00 1.28 3.50
20
0.68 1.60 0.81 1.80 1.00 2.20 1.20 2.50 1.32 3.00
10
0.74 1.45 0.85 1.60 1.06 1.85 1.25 2.10 1.40 2.50
OPEN
0.75 1.40 0.87 1.50 1.10 1.80 1.33 2.00 1.50 2.40
PERFORMANCE MEASURED WITH FLOODED INLET (0 PSI), 70°F (21°C) AMBIENT AND WATER TEMPERATURE, AND VOLT
-
AGE CONTROLLED AT 12 VDC. POSITIVE INLET PRESSURE WILL INCREASE THE DISCHARGE PRESSURE BY A SIMILAR
AMOUNT, FOR A GIVEN FLOW. MAXIMUM INLET PRESSURE IS 60 PSI.
SHADED AREA DENOTES CONTINUOUS OPERATION CAPABILITY AT DESIGNATED PRESSURE AND CURRENT.
All of the pump models in the Performance Data and Heat Rise charts are in the shaded area, meaning they are capable of
sustaining continual running, at any of the above listed pressures, without shutting down to allow the motor to cool. To
conserve wearing parts, however, the pump should only operate as needed.
ALL PERFORMANCE AND HEAT RISE FIGURES ARE APPROXIMATE. ACTUAL VALUES WILL VARY WITH AMBIENT CONDITIONS.
Series 5800 Pump
Model: 58XX-7X01-B664
HEAT RISE
60
80
100
120
140
160
180
200
0 10 20 30 40 50 60 70 80 90 100 110 120
TIME (MINUTES)
5.6 AMPS
RECOMMENDED
SHUT-OFF
TEMPERATURE