Specifications

Pre Installation Review
Location Specications:
• Not intended to be used to treat water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
Hardness in grains:________________ Estimated Water Usage: __________
Iron in parts per million: ____________ Service Line Size: _______________
Notes: __________________________________________________________
Requirements for Proper Operation:
Water Pressure: A minimum water pressure
of 20 psi and a maximum of 125 psi must be
supplied to the equipment.
Flow Rate: A minimum of 5 gallons per minute
is required for equipment to work properly. If
you have less than 5 gal./min., consult with
factory for special settings.
Water Temperature: The water temperature
operating range is a minimum of 35˚ F and
a maximum of 100˚ F. The system and drain
must be protected from freezing.
Drain: A drain must be within 20 ft. of the
installation. There must be a proper back-
siphon provision put in place.
Electricity: Plug sytems into a standard 110
volt outlet. System uses 110 v - 60 hz - 3watts
Tips for Maximizing the Benets From the Series 9000:
Salt: By using a clean grade of salt, you can
reduce or eliminate brine tank clean outs. If
you have iron in your water, using an iron
inhibiting salt can help. Always keep the salt
level above the water level in the brine tank.
Power: In the event of a power outage,
check
the timer for the current time and adjust if
necessary.
Bypass: If you require well or pump work,
always bypass your Series 9000 until the
work is nished and the water runs clear.
Sand: If sand is present, use a special
lter to remove the sand before the system.