Specification

For technical/installation literature, call (800) 877–2005 or visit www.aquaticbath.com
TECHNICAL SPECIFICATIONS
MARRATTA
60 x 43
1
4 x 20
1
4 (1525 x 1100 x 515)
inches (mm)
Builders’ Choice Series • Fax on Demand #5049
42"
43 1/4"
60"
19"
1 1/4"
1
2
3
4
5
A
13 5/8”
43"
52"
23"
26"
52˚
B
SUMP DATA inches (mm)
Capacity to
Overflow
gal (ltr)
Min. Operating
Capacity
gal (ltr)
WIDTH @ centerline DEPTH @ centerline
Top Bottom Top Bottom
72 (273) 52 (197) 52 (1320) 43 (1092) 26 (660) 23 (585)
DIMENSIONS inches (mm)
Width
Overall / Net
Depth
Overall / Net
Height
Overall / Net
Skirt
Height
60 (1525)
43
1
4 (1100) /
42 (1065)
20
1
4 (515) /
19 (485)
19 (485)
Rev. 03.12.14
ELECTRICAL DATA
Component Specification Requirement
Pump
.75 HP; 5 AMP; 120 V
15 AMP; 120V, separate circuit;
Class A GFCI
Optional Heater
(whirlpool model)
1.5KW; 12 AMP; 120 V
15 AMP; 120V, separate circuit;
Class A GFCI
Heated Blower 5 AMP; 120 V
15 AMP; 120V, separate circuit;
Class A GFCI
Each air bath is equipped with an air heating system to raise the temperature of the air entering
the bath. This air temperature will be lower than the bathing temperature of the water, but will
help reduce rapid decrease in water temperature. In addition, the air coming from the air jets
will feel cool against the skin. This system does not heat the water.
FEATURES lbs (kg) Dimensional Tolerance ± 38”.Dimensions needed for site preparation should be measured from the unit.Aquatic assumes no responsibility for preparatory work.
Type and Model # Material Jets Pump Air System Heater Controls Drain Pkg. Wt.
Soaker #7260420 Acrylic 0 LH or RH 127 (58)
Whirlpool #7260421 Acrylic 8 0.75 HP
1.5kW inline
(optional)
Pneumatic LH or RH 177 (80)
Air Bath #7260420A Acrylic 0 Channel Inline Pneumatic LH or RH 157 (71)
PLUMBING DIMENSIONS inches (mm)
A B
Drain
to Overflow
Drain
Diameter / Clearance
2 (50) 9
3
8 (240) 13
5
8 (345) 2 (50) / 1
3
8 (35)
NOTES:
1) Where applicable, utilize cut-out templates packed
with unit for deck cutouts.
2) 16 x 16 (405 x 405) minimum access required
at pump/blower location(s).