System Test:
To test system, follow these steps in order listed:
1. Fill clean tub with water to minimum 4” above air channels.
2. To test the Ground-Fault Circuit-Interrupter (GFCI), push the test button. The GFCI should interrupt power. Push the
reset button. Power should be restored. If the GFCI fails to operate in this manner, there is a ground current flowing,
indicating the possibility of a lethal electric shock. Do not use this unit. Disconnect the unit and have the problem
corrected by a licensed electrician before using.
3. Push on/off button on the air bath unit.
4. Allow system to run a full 10-minutes.
5. Through access door or removable skirt, check for leaks in air bath plumbing system. Make sure half-union at blower
is hand-tight. If leakage is occurring at any other points, notify distributor.
6. If any electrical malfunctions occur, consult electrician. Malfunctions of the air bath controls or the circulating system
should be reported to the distributor who supplied the air bath.
Clean-up:
1. Remove all construction residue and foreign materials. Wipe unit clean with a damp rag, otherwise staining
may occur.
2. Plaster may be removed by scraping with the edge of a piece of wood or rigid plastic. Do not use metal scraper.
For spots left by plaster or grout: rub lightly with a liquid detergent (Spic-N-Span
®
or similar) on damp cloth
or sponge.
3. DO NOT use abrasive cleaners, scouring powders, steel wool, wire brushes or anything else that may harm or dull
the surface.
4. Paint, tar, or stubborn stains may be removed with rubbing alcohol. To avoid discoloration, cleaners containing
petroleum distillates must not remain on surfaces. NEVER use lacquer thinner or chlorinated solvents.
5. Dulled areas can be restored to a high gloss with white or a non-abrasive automotive rubbing compound, followed
by application of carnauba wax or white or cream automotive paste wax and buffing.
6. Major gouges require professional repair. Contact Aquatic to arrange factory-authorized repair services.