Full Product Manual

Aquatic 21
Builders’ Choice Air Owner's Manual & Installation Guide
TROUBLESHOOTING GUIDE
WARNING: Always turn off power at the main electrical service panel when servicing your air bath.
SYMPTOMS POSSIBLE PROBLEMS SUGGESTED SOLUTIONS
Air bath system does not operate: 1) No power to air bath unit.
2) GFCI or circuit breaker is in OFF position.
3) Air tube is pinched/slit
4) Air tube is disconnected or loose
5) Defective starting switch inside blower.
1) Reset circuit breakers and GFCI if tripped. Check
fuses and replace if bad.
2) Reset GFCI.
3) Visually inspect air tube for kinks or slits.
4) Check air tube connections at blower and at bottom.
5) Contact Aquatic.
Blower turns off by itself or before time
elapses:
1) Blower motor overheated and thermal protection
device has deactivated motor (possibly low voltage).
2) GFCI tripped.
1) Check that the blower has sufficient ventilation and
that the intake to the blower is not blocked. Clear and
allow motor to cool down. (check service and
wire size.)
2) Refer to installer/dealer/electrician.
Circuit breaker trips repeatedly: 1) Defective breaker.
2) Short circuit between bath and breaker box.
3) Other items are connected to the same circuit.
1) Contact electrician.
2) Contact electrician.
3) Contact electrician.
Blower does not manually shut off: 1) Defective On/Off button.
2) Disconnected air hose.
3) Air tube is pinched/slit.
1) Refer to installer/dealer. Shut breaker off.
2) Contact Aquatic.
3) Visually inspect air tube for kinks/slits.
Blower does not reach full speed: 1) On/Off switch is partially depressed.
2) Low voltage.
1) Press On/Off switch once; press again for only
1/2 second.
2) Contact electrician.
Water leakage: 1) Call a plumber to determine and correct source of leak.
If plumber determines that air bath system is at fault,
notify Aquatic Technical Services at (800) 945-2726 to
arrange a repair service call.