PRE-PLANNING ACCESS, PLUMBING AND ELECTRICAL INSTALLATION
1. Sufficient clearance must be provided for access to service connections: blower and electrical hook-ups. (Minimum
unobstructed access 14” x 18”)
A. Alcove Installation (with optional skirt): Access is provided by removing the skirt. To permit removal of skirt, allow
at least 6” clearance at both ends of tub: vanity, toilet, etc., must not obstruct skirt removal.
B. Island or Pier Installations: Provide access panel at motor end. [See diagrams on pages 8-9.]
C. Sunken Installations: Provide access panel in floor or in ceiling below.
2. Drain/waste pipe stub must be located in wall or floor to match location of drain, waste and overflow
kit tee fitting. Provide a 6” x 12” box-out in sub-floor or slab.
3. When fittings (spout, handles, valves, etc.) are to be mounted on the unit, be certain that the hot and cold water
copper supply lines are located where there is ample room for mounting before setting the unit in place.
4. WARNING: When using electrical products, basic precautions should always be followed, including the
following:
A. DANGER: Risk of Lethal Electrical Shock. Connect only to a separate circuit protected by a Ground-Fault
Circuit-Interrupter (GFCI).
B. Connection. Electrical hook-up must be performed by a licensed electrician in accordance with local,
state and national electrical codes.
C. Access Panel Required. For built-in custom units, provide an access panel for servicing electrical components.
[See FRAMING & INSTALLATION PROCEDURES on page 10].
BEFORE YOU START
IMPORTANT: Observe all governing codes and ordinances.
1. Proper installation is your responsibility. Have a qualified technician install this bath.
2. Installation using a Ground-Fault Circuit-Interrupter (GFCI) is required. [See ELECTRICAL CONNECTIONS on pages
12-13.]
3. It is your responsibility:
To contact a qualified electrical installer.
To assure that electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA
70 - latest edition.
Copies of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02169
(617) 770-3000