Specification

Customer Service: 800.945.2726 • aquaticbath.com
TECHNICAL SPECIFICATIONS
CARIANI
72 x 42 x 19 inches
Builders’ Choice Series
43 1/4"
42"
19"
72"
1 1/4"
1
2
3
4
5
64 3/4"
56"
21"
27"
A
13 5/8”
50˚
B
SUMP DATA inches
Capacity to
Overflow
gal
Min. Operat-
ing Capacity
gal
WIDTH @ centerline DEPTH @ centerline
Top Bottom Top Bottom
74 60 64
3
4 56 27 21
DIMENSIONS inches
Width
Overall / Net
Depth
Overall / Net
Height
Overall / Net
Skirt
Height
72
43
1
4 / 42 20
1
4 / 19 19
ELECTRICAL DATA
Component Specification Requirement
Pump
5 AMP; 120 V
15 AMP; 120V, separate circuit;
Class A GFCI
Optional Heater
(whirlpool model)
1.5KW; 12 AMP; 120 V
15 AMP; 120V, separate circuit;
Class A GFCI
Heated Blower 5 AMP; 120 V
15 AMP; 120V, separate circuit;
Class A GFCI
Each air bath is equipped with an air heating system to raise the temperature of the air entering
the bath. This air temperature will be lower than the bathing temperature of the water, but will
help reduce rapid decrease in water temperature. In addition, the air coming from the air jets
will feel cool against the skin. This system does not heat the water.
FEATURES Dimensional Tolerance ± 38”.Dimensions needed for site preparation should be measured from the unit.Aquatic assumes no responsibility for preparatory work.
Type and Model # Material Jets Pump Heater Controls Drain
Pkg. Wt.
lbs
Soaker #8072620 Cast Acrylic 0 LH or RH 141
Whirlpool #8072621 Cast Acrylic 8 63 GPM
1.5kW inline
(optional)
Pneumatic LH or RH 191
Air Bath #8072620A Cast Acrylic 0 Inline Pneumatic LH or RH 171
PLUMBING DIMENSIONS inches
A B
Drain
to Overflow
Drain
Diameter / Clearance
2
1
4 8
5
8 13
5
8 2 / 1
1
4
NOTES:
1) Where applicable, utilize cut-out templates packed
with unit for deck cutouts.
2) 16 x 16 minimum access required at pump/blower location(s).