MILLENNIUM SERIES OWNER’S MANUAL & INSTALLATION GUIDE Installer: This booklet must be given to the product owner. Please add important information below. Model # ___________________________________ Purchase Date ___________________________________ Serial # ___________________________________ Distributor ___________________________________ Note: Read all instructions before proceeding with installation. All specifications are ± 3/8’’ and are subject to change without notice.
TABLE OF CONTENTS PRODUCT WARRANTY REGISTRATION INFORMATION IMPORTANT SAFETY INSTRUCTIONS 3 4–5 USER INFORMATION 6 FCC INFORMATION 6 AQUATIC LIMITED LIFETIME WARRANTY 7 INSTALLATION INSTRUCTIONS Pre-Installation Procedures Structural Preparation Fast-Fill Waterfall Spout Plumbing Electrical Installation Inline Maintenance Heater Wiring and Operating Instructions Final System Test & Clean-Up OPERATION Bathside Control Systems Jet Operations Dual Sided Remote Control Installation 8 9 10 10 11 –
AQUATIC Product Warranty Registration Information Thank you for choosing an Aquatic bath. You have chosen one of the finest bath products in the industry! Aquatic supports your purchase with strong commitments to quality and customer satisfaction. IMPORTANT! To activate Product Warranty please register with Aquatic. Your product warranty must be registered and confirmed with Aquatic through the Serial Number on your unit. To register, please contact Aquatic. (800) 945--2726 • www.aquaticbath.
Millennium Owner's Manual & Installation Guide IMPORTANT SAFETY INSTRUCTIONS WARNING: When using this unit, basic precautions should always be followed. Failure to follow these instructions could result in personal injury, electric shock, or fire. READ AND FOLLOW ALL INSTRUCTIONS: • WARNING: Risk of lethal electric shock. To reduce risk of electric shock, connect only to circuits protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD).
Millennium Owner's Manual & Installation Guide IMPORTANT SAFETY INSTRUCTIONS WARNING: WHEN USING THIS UNIT, THESE BASIC PRECAUTIONS SHOULD BE FOLLOWED. This manual contains information and instructions for proper operation and maintenance of your bath. Failure to follow these instructions could result in personal injury, electrical shock or fire. READ AND FOLLOW ALL INSTRUCTIONS DANGER! TO REDUCE THE RISK OF INJURY: 1.
Millennium Owner's Manual & Installation Guide USER INFORMATION PLEASE NOTE: WHIRLPOOL USER INFORMATION • PLEASE NOTE: The whirlpool action may cause even small amounts of bubble bath or shampoo to foam excessively. Exercise moderation in experimenting with different soap products. No servicing of this product should be done by the user. There are no user serviceable parts. All controls are located in the control recesses on the lip of the tub.
Aquatic Limited Lifetime Warranty FOR MILLENNIUM SERIES BATHS LIMITED WARRANTY FOR ORIGINAL CONSUMER FOR HOUSEHOLD USAGE WHAT PRODUCTS ARE COVERED Structures and surface finishes, pumps and blowers on the Millennium Series.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION PRE-INSTALLATION PROCEDURES PLEASE NOTE: THE MANUFACTURER ACCEPTS A +3/8” VARIANCE. THERE ARE VARIATIONS ON EACH TUB AND SPECIFICATIONS ARE SUBJECT TO CHANGE AS WE IMPROVE UPON OUR PRODUCT AS REQUIRED. THE DIMENSIONS NEEDED FOR SITE PREPARATION AND STRUCTURE BUILDINGS SHOULD BE MEASURED FROM THE TUB; AQUATIC, ASSUMES NO RESPONSIBILITY FOR PREPARATORY WORK.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS STRUCTURAL PREPARATION Note: The bath should remain in its shipping carton until time of installation. 1. Literature dimensions are for reference only. INSTALLATION DIMENSIONS SHOULD BE TAKEN DIRECTLY FROM THE TUB.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS FAST-FILL WATERFALL SPOUT The Fast-Fill Waterfall Spout will be stubbed as in Figure 2B. WARNING: DO NOT OVER TIGHTEN! DO NOT USE TEFLON TAPE. Damage to fitting is not covered under warranty. 2B 2A FROM VALVES Fast-Fill Waterfall Spout is stubbed out with a 3/4" female threaded brass fitting. PLUMBING 1.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS NOTE: BEFORE BATH IS USED, THE AIR-WHIRLPOOL SYSTEM SHOULD BE CLEANED IN ACCORDANCE WITH THE PROCEDURES ON PAGE 23 OF THIS MANUAL. ELECTRICAL INSTALLATION WARNING: ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRICIAN, IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS ELECTRICAL INSTALLATION (CONT.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS ELECTRICAL INSTALLATION (CONT.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS INLINE MAINTENANCE HEATER WIRING AND OPERATING INSTRUCTIONS The air-whirlpool Inline Maintenance Heater is totally self-contained to ensure trouble free operation. The heater will maintain the temperature of the water in the bathtub. As with all electrical devices, certain safety precautions should be taken during wiring and use. Please read and follow all these instructions carefully.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS FINAL SYSTEM TEST & CLEAN-UP System Test To test system, follow these steps in order listed: 1. Fill clean tub with water to a point no less than 2” (50) above the highest jet. 2. To test the Ground-Fault Circuit-Interrupter (GFCI), push the test button. The GFCI should interrupt power. Push the reset button. Power should be resorted.
Millennium Owner's Manual & Installation Guide OPERATION NOTE: DO NOT START PUMP UNTIL ALL JETS ARE SUBMERGED. WATER LEVEL SHOULD BE 2” ABOVE HIGHEST JET. BATHSIDE CONTROL SYSTEMS 3: SEQUENCER MASSAGE MODE 2: BLOWER & CYCLE 4: SPEED INCREASE 5: SPEED DECREASE 1: ON/OFF PUMP 6: CHROMATHERAPY KEYPAD SIDE A OR KeyPad A Functions LED 1: ON/OFF PUMP 1st Press:The pump starts ON 2nd Press:The pump stops OFF 2: BLOWER & CYCLE 1st Press: Blower starts at high speed.
Millennium Owner's Manual & Installation Guide OPERATION BATHSIDE CONTROL SYSTEMS (CONT.) KeyPad A Functions SEQUENCER MODE A The BackJet row shown will be at ON during the cycle: Backjet row 1, 2, 3, 4, 3, 2 and repeats the sequence. SEQUENCER MODE B The BackJet row shown will be at ON during the cycle: Backjet row 1-2-1-2 All Off, 1-2-1-2 All Off. SEQUENCER MODE C The BackJet row shown will be at ON during the cycle: Backjet row 3-4-3-4 Off, 3-4-3-4 All Off.
Millennium Owner's Manual & Installation Guide OPERATION NOTE: DO NOT START PUMP UNTIL ALL JETS ARE SUBMERGED. WATER LEVEL SHOULD BE 2” ABOVE HIGHEST JET. BATHSIDE CONTROL SYSTEMS (CONT.
Millennium Owner's Manual & Installation Guide OPERATION JET OPERATIONS All Millennium Series jets are removable and can simply be put into the dishwasher for cleaning. Note: Use dishwasher top rack and remove before the drying cycle starts. The Millennium Series features Aquatic’s exclusive Shiatsu Back Jetting System, Pressure Plus Jets and Pressure-Flo Hydrotherapy Jets. Shiatsu Back Jetting System To adjust pressure (see Figure 3A): 1. Grasp the outer ring of the jet. 2.
Millennium Owner's Manual & Installation Guide OPERATION JET OPERATIONS (CONT.) Pressure Plus Jets To adjust pressure (see Figure 4A): 1. Grasp the outer ring of the jet. 2. Turn the jet clockwise to increase flow, counter-clockwise to shut off. To remove jet (see Figure 4B): 1. Grasp the outer ring of the jet. 2. Turn the jet counter-clockwise, until the jet clicks, then pull. 4A To replace or change jet (see Figure 4B): 1. Insert the jet into jet housing. 2.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS DUAL SIDED REMOTE CONTROL INSTALLATION Receiver Module Installation the Receiver Module and remote may be used in conjunction with the supplied keypad or without. The two receiver modules must be installed under the bathtub rim. RECEIVER MODULES IMPORTANT: In order to obtain the best reception possible, we recommend not to install the receiver module next to the faucets or metal piping.
Millennium Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS DUAL SIDED REMOTE CONTROL INSTALLATION (CONT.) Remote Control Installation The following components are necessary • 1 remote control • 2 magnets • 1 receiver module • 1 cable 1. Determine the appropriate location for the remote control in the bathtub. 2. Determine backside location of magnets A. Hold the remote control in the chosen location. B.
Millennium Owner's Manual & Installation Guide TUB CARE MAINTENTANCE Before tub is used, the air-whirlpool system should be cleaned and disinfected. Remove all debris and clean tub before putting whirlpool into service. DO NOT USE ABRASIVE CLEANERS ON THE ACRYLIC FINISH. Use a non-abrasive detergent and rinse well after cleaning. • Fill the tub with HOT water to a level 2” above the highest jet.
Millennium Owner's Manual & Installation Guide TUB CARE Surface Scratch Removal Minor scratches may be removed by polishing your tub with a non-abrasive car polish, followed by buffing. Deeper scratches can be removed by: • Sanding with wet 400 grit sandpaper. • Sanding with wet 600 grit sandpaper. • Sanding with wet micro-grit sandpaper. • Buff out using car polish. REPAIR The service of your air-whirlpool bath should be performed only by a qualified service technician.
Millennium Owner's Manual & Installation Guide WATER QUALITY CHEMICAL & WATER QUALITY Owners of fill and drain air bathtubs need to know basic information concerning water quality, how it affects the performance and enjoyment of the operation of their tubs, and steps that can be taken by the owner to correct related problems. Important issues are the microbiological and chemical quality of the water. 1.
Millennium Owner's Manual & Installation Guide WATER QUALITY occurs, you need to contact the water supplier to determine the iron content and/or corrosion potential of the water and follow their suggestions for treatment. If you are on an individual well you need to contact the water treatment company to test your water and suggest solutions if a problem is present. Manganese - Manganese is found in many natural waters especially from wells.
Millennium Owner's Manual & Installation Guide TROUBLESHOOTING GUIDE WARNING: Always turn off power at the main electrical service panel when servicing your whirlpool. SYMPTOMS POSSIBLE PROBLEMS SUGGESTED SOLUTIONS Motor does not start 1) 2) 3) 4) 5) 6) 7) 1) 2) 3) 4) 5) 6) 7) Motor does not reach full speed 1) Low voltage. 2) Motor windings connected for wrong voltage. 3) Wiring too small. 1) Contact your electrician. 2) Contact Aquatic. 3) Contact your electrician.
Millennium Owner's Manual & Installation Guide REPLACEMENT PARTS LIST ILLUSTRATION # PART NUMBER DESCRIPTION 1A 8451CONTROL CONTROL BOX;CHROMATHERAPY;MILL 1B. 8020LIGHTS CHROMATHERAPY;20LEDS BULB;RND CLR 1C. 1D. (PACKAGED WITH 1B) LENS REMOVAL TOOL 20LEDS CHROMATHERAPY BULB 2A. 8186ASSYxx FULL SIZE DIRECTIONAL JET 2B. 8186VJTB V-JET BODY 8186BDY 90 DEGREE JET BODY 8186WFTG WALL FITTING 3A. 1120xx 150GPM SUCTION COVER 3B. 1122NUT 150GPM SUCTION NUT 3C.
Millennium Owner's Manual & Installation Guide REPLACEMENT PARTS LIST ILLUSTRATION # PART NUMBER DESCRIPTION 11A. 8511FTG 3/4” TEE 11B. 8514FTG 3.4” ST 90 EL 12A. 8504FTG 3/4” WYE 22.5 DEG 13A. 1092 3/8” PVC AIR TUBING 13B. 8038TEE 3/8” BARB TEE; AIR 14A. 8012CVALVE 14MM ILLUSION CHECK VALVE 14B. --- 14MM ILLUSION JET STOPPER 14C. --- 14MM ILLUSION JET BODY 14D. --- 14MM ILLUSION WASHER 14E. 8012TEE ILLUSION TEE 14F. 8012ELBOW ILLUSION ELBOW 15A.
Millennium Owner's Manual & Installation Guide REPLACEMENT PARTS MAP 10. 9. 8a. 8b. 1a. 8c. 1c. 7a. 7b. 7c. 7d. 1b. 6a. 6b. 6c. 1d. 5a. 2b. 2a. 30 5b. 5c. 3a. 3a. 3b. 3c. 4a. 4b. 4c.
Millennium Owner's Manual & Installation Guide REPLACEMENT PARTS MAP 11a. 12. 13a. 13b. 11b.
Millennium Owner's Manual & Installation Guide REPLACEMENT PARTS MAP 14a. 14b. 14d. 14c. 14e. 32 14f.
Millennium Owner's Manual & Installation Guide REPLACEMENT PARTS MAP 20a. 20c. 15b. 20b. 15c. 15a. 16e. 16a. 16b. 16c. 16f. 16d. 19a. 17a. 18a. 19b. 18b. 21b. 21c. Aquatic 19c. 21a. 21d.
Revision #007 5/06 AQUATIC Fax-On-Demand System: Toll Free (877) 618-7024 8101 E. Kaiser Blvd., Suite 200 • Anaheim, CA 92808 (800) 945-2726 • Fax (866) 544-5353 • www.aquaticbath.com 8MANMIL | F.O.D. #9000 | Rev.