Following the 20 minute run time of the blower, there will be a 15 minute idle period. The blower will then turn on
for 3 minutes for the purge cycle. If the user turns the blower off manually before the timer reaches 20 minutes, the
idle period will start after the blower has been turned off. During the 15 minute idle period and the 3 minutes
purge, the light indicator of the on/off button will blink. During the idle period, pressing the on/off button will turn on
the blower in constant mode. During the 3 minute purge, pressing the blower key will stop the purge.
It is possible for the user to program a purge cycle that will start every day for a duration of 1 minute. Aquatic
strongly recommends activating this feature. The purge cycle will help ensure that the air channels stay dry even
when you have taken a soaking bath or shower.
To activate this purge feature, the user must hold down the “+” button for 5 seconds when the blower/heater is off
or waiting for the normal purge. Then, the light indicator on the on/off button will blink twice. If the unit was in
standby for a normal purge when the 24 hour purge was activated, the normal purge will be cancelled.
To show the user that the 24 hour purge is activated, the light indicator on the on/off button will blink at a slow rate.
A different blinking rate was picked in order to make it easier for the user to differentiate it from the standby of the
regular purge cycle.
The purge will be done every day at the same time the user activated it (pressed the “+” button). By pressing the
“+” button again, the 24 hour purge will be deactivated and the light indicator on the on/off button will stop blinking
and turn off.
3. In constant mode, pressing and holding the “+” button will increase the variable speed of
the blower to the maximum. Pressing and holding the “ —” button will reduce the blower’s variable speed to
the minimum. In both cases, the user can release the button at the desired power level. Note: In wave mode
or pulse mode, the “+” or “—” buttons will work the same way but will have an effect on the maximum power of
the wave and pulse mode.