Specification Sheet

For technical/installation literature, call (800) 877–2005 or visit www.aquaticbath.com
TECHNICAL SPECIFICATIONS
INFINITY 7
71
1
8 x 40
1
4 x 30 (1805 x 1020 x 760)
inches (mm)
23
1
4
40
1
4
30
27
1
2
20
1
2
71
1
8
Pump
40
1
4
Blower
No alternate pump location available.
*Shown with optional air system.
Fill Spout Location*
Back Angle 36º
Back Angle 19º
14
17
15
5
4
Innity Series • Fax on Demand #1197
FEATURES lbs (kg) Dimensional Tolerance ± 38”. Dimensions needed for site preparation should be measured from the unit. Aquatic assumes no responsibility for preparatory work.
Type and Model # Material Jets Pump Air System Blower Heater Controls Drain Pkg. Wt.
Whirlpool #AI7INF7242 Acrylic 16
2 HP
Injector
(optional)
Variable speed
(optional)
1.5 kw Inline
Electronic Center Front 424 (190)
DIMENSIONS inches (mm)
Width
Overall / Net
Depth
Overall / Net
Height
Overall / Net
Skirt
Height
71
1
8 (1805) 40
1
4 (1020) 30 (760)
SUMP DATA inches (mm)
Capacity to
Overflow
gal (ltr)
Min. Operating
Capacity
gal (ltr)
WIDTH @ centerline DEPTH @ centerline
Top Bottom Top Bottom
134 (510) 96 (365) 63
1
4 (1620) 41
1
2 (1055) 28
1
2 (725) 26 (660)
PLUMBING DIMENSIONS inches (mm)
A B
5 (130) 11 (280)
B
A
NOTES:
1) Where applicable, utilize cut-out templates packed
with unit for deck cutouts.
2) 16 x 20 (405 x 510) minimum access required
at pump/blower location(s).
ELECTRICAL DATA
Component Specification Requirement
Pump 2 HP; 12 AMP; 110 V
15 AMP 2 pole, separate circuit,
Class A GFCI
Inline Heater 1.5 kW; 12.5 AMP; 110 V
Blower 1 HP; 10.5 AMP; 110 V
15 AMP 1 pole, separate circuit,
Class A GFCI
This unit has a
3
4” female waterfall ll spout connection.