Note: Read all instructions before proceeding with installation. All specifications are ± 1/4’’ and are subject to change without notice. Dimensions listed in inches (mm).
LuxeAir Series Owner's Manual & Installation Guide TABLE OF CONTENTS PRODUCT REGISTRATION INFORMATION CONGRATULATIONS! 3 4 SAFETY INSTRUCTIONS 5 INSTALLATION INSTRUCTIONS Pre-Installation Procedures Structural Preparation Factory Installed Tile Flange LuxeAir 31& 32 Integrally Skirted Baths Installation Procedures for Integrally Skirted Models Removable Skirt Panels for Integrally Skirted Models Plumbing Rough-In Measurements Electrical Installation Component Breakdown 6 7-8 8 8 9 9 10 10 11-12 13-14
LuxeAir Series Owner's Manual & Installation Guide AQUATIC Product Registration Information Your product warranty is registered and confirmed with Aquatic through the Serial Number on your unit. You do not need to contact Aquatic to confirm registration. Please fill out the information below and reference when contacting the distributor to expedite warranty claims.
LuxeAir Series Owner's Manual & Installation Guide CONGRATULATIONS! You have chosen one of the finest bath products in the world! Aquatic supports your purchase with strong commitments to quality and customer satisfaction. Please read and follow all of the instructions contained in this Owner’s Manual before installing, operating or maintaining your whirlpool. In addition, you should continually refer to these instructions during the life of your whirlpool.
LuxeAir Series Owner's Manual & Installation Guide SAFETY INSTRUCTIONS WARNING: WHEN USING THIS UNIT, THESE BASIC PRECAUTIONS SHOULD BE FOLLOWED. This manual contains information and instructions for proper operation and maintenance of your whirlpool. Failure to follow these instructions could result in personal injury, electrical shock or fire. READ AND FOLLOW ALL INSTRUCTIONS DANGER! TO REDUCE THE RISK OF INJURY: A.
LuxeAir Series Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION PRE-INSTALLATION PROCEDURES WARNING: All units are shipped with loose unions. Before attempting to test, install or use your whirlpool, all pump and heater unions and “O” rings must be repositioned and/or tightened. PLEASE NOTE: THE MANUFACTURER ACCEPTS A 1/4” VARIANCE.
LuxeAir Series Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS STRUCTURAL PREPARATION Note: The bath should remain in its shipping carton until time of installation. 1. Literature dimensions are for reference only. Installation dimensions should be taken directly from the tub. An access panel of 30”w x 20”h minimum must be provided at the pump end of the whirlpool allowing sufficient clearance to make final connections and for servicing the pump, blower, heater and control units.
LuxeAir Series Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS STRUCTURAL PREPARATION (CONTINUED) 5. When placing the tub on a platform or cut out, the opening should be 1” smaller than the specified rim dimensions. Extreme care must be taken in this type of installation to ensure the tub will come to rest entirely on the leveling feet or ABS Support Base. 6. IF YOU HAVE PURCHASED A WHIRLPOOL WITH AN INSTALLED TILE FLANGE, PROCEED TO INSTRUCTION “2A”.
LuxeAir Series Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS INSTALLATION PROCEDURES FOR INTEGRALLY SKIRTED MODELS 1. To avoid obstructions during installation, make sure water lines, spout pipes and valve plumbing do not project into alcove. 2. Ledger Strip: Fasten a 1” x 3” (25mm x 75 mm) ledger strip along rear for alcove and along both sides in corner installations at Dimension LH. (see Figure 3A) 3.
LuxeAir Series Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS PLUMBING 1. After securing tub in place, normal waste and overflow and valves are installed per normal plumbing procedures, in accordance with all state and local standards. 2. Install standard 1-1/2” trap to drain and overflow. Before proceeding, make a final operational check by filling tub with water to overflow and operate pump for 5 minutes. Check for leaks carefully both while pump is running and has been turned off.
LuxeAir Series Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS ELECTRICAL INSTALLATION WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRICIAN, IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES. WARNING: When using electrical products, precautions should always be followed, including the following: DANGER: RISK OF ELECTRIC SHOCK! GFCIs are not supplied, however we do specify their use.
LuxeAir Series Owner's Manual & Installation Guide INSTALLATION INSTRUCTIONS ELECTRICAL INSTALLATION (CONTINUED) Red Load White Neutral 15amp 2 pole GFCI Breaker Pump on off Heater Ground Black Load Black Load 15amp 1 pole GFCI Breaker White Neutral Blower Ground TEST RESET Figure 6 BONDING WIRE: Connect a #8 bare copper bonding wire from the pump motor to the heater and then to the cold water plumbing or other suitable ground. Grounding is required. Grounding is NOT required for the blower.
LuxeAir Series Owner's Manual & Installation Guide LuxeAir Series component breakdown Pump Controller No Chromatherapy GECKO OUTPUT INPUT TEST RESET Blower Controller TEST RESET GECKO OUTPUT INPUT HEAT MASTER 1.
LuxeAir Series Owner's Manual & Installation Guide LuxeAir Series component breakdown With Chromatherapy Pump Controller GECKO LED Light OUTPUT INPUT TEST RESET Blower Controller On/Off Pump Button TEST RESET GECKO OUTPUT INPUT HEAT MASTER 1.
LuxeAir Series Owner's Manual & Installation Guide OPERATION NOTE: DO NOT START PUMP UNTIL ALL JETS ARE SUBMERGED. WATER LEVEL SHOULD BE 2” ABOVE HIGHEST JET. JET OPERATIONS All LuxeAir Series jets are removable, and can simply be put into the dishwasher for easy cleaning. (Note: use top rack and remove before drying cycle.
LuxeAir Series Owner's Manual & Installation Guide OPERATION INLINE MAINTENANCE HEATER OPERATING INSTRUCTIONS Operation of the inline maintenance heater is completely automatic. The heater will help maintain the temperature of the water in the whirlpool. The heater includes the following components. THERMOSTAT: The “Smart Thermostat” requires no adjustment and will automatically maintain the water temperature at 102o F - 104o F. If the whirlpool is too warm, simply adjust by adding cold water.
LuxeAir Series Owner's Manual & Installation Guide OPERATION BATHSIDE CONTROL SYSTEMS To Turn Blower (Air System) On: Press once to turn the blower (air system) on. A second press will turn the blower off. Holding the button down for 2 seconds will change modes when the blower is on. There is a 20 minute timer that will automatically turn the blower off. Press once to turn the pump (jets) on. A second press will turn the pump off. There is a 20 minute timer that will automatically turn the pump off.
LuxeAir Series Owner's Manual & Installation Guide OPERATION BATHSIDE CONTROL SYSTEMS W/ OPTIONAL CHROMATHERAPY Electronic Control Panel: (see Figure 11): 1. To Turn Air Bath System On: Pressing the ”On/Off” button will turn the blower on in “constant mode.” The light indicator will illuminate when the system is on. The blower and the heater will automatically shut off after a 20-minute period. 2.
LuxeAir Series Owner's Manual & Installation Guide OPERATION BATHSIDE CONTROL SYSTEMS W/ OPTIONAL CHROMATHERAPY (CONT.) Purge 24 Hours: It is possible for the user to program a purge cycle that will start every day for a duration of 1 minute. Aquatic strongly recommends activating this feature. The purge cycle will help ensure that the air channels stay dry even when you have taken a soaking bath or shower.
LuxeAir Series Owner's Manual & Installation Guide OPERATION TO REPLACE LED LIGHT: 1. Disconnect the power to your bathtub. 2. Drain the bathtub. 3. Open the lens of the fixture using ONLY the proper tool provided for that purpose. Do not attempt to remove the lens without the provided tool. Lens Install & Removal Tools 4. Replace your LED light (replacement LED lights can be obtained from Aquatic). 5. Verify “O” ring is not damaged and is properly positioned in the groove when replacing the lens.
LuxeAir Series Owner's Manual & Installation Guide CARE AND MAINTENANCE INITIAL CLEANING Before tub is used, the whirlpool system should be cleaned and disinfected. Remove all debris and clean tub before putting whirlpool into service. DO NOT USE ABRASIVE CLEANERS ON THE ACRYLIC FINISH. Use a non-abrasive detergent and rinse well after cleaning. • Fill the tub with HOT water to a level 2” above the highest jet.
LuxeAir Series Owner's Manual & Installation Guide CARE AND MAINTENANCE JET CLEANING All LuxeAir Series jets are removable, and can simply be put into the dishwasher for easy cleaning. See Jet Operation Instructions for removal, page 15. (Note: Use top rack of dishwasher and remove before the drying cycle starts.) SURFACE SCRATCH REMOVAL Minor scratches may be removed by polishing your tub with a non-abrasive car polish, followed by buffing.
LuxeAir Series Owner's Manual & Installation Guide CARE AND MAINTENANCE WATER QUALITY ISSUES (CONTINUED) Pigmented Bacteria- Water utilities from all over the United States have experienced calls from consumers inquiring and complaining about pinkish substance on bathroom fixtures that is very persistent, appearing in the shower, sink and along the water line of toilet bowls. With whirlpool bathtubs, the formation of this colored substance may be particularly pronounced in white tubs.
LuxeAir Series Owner's Manual & Installation Guide CARE AND MAINTENANCE WATER QUALITY ISSUES (CONTINUED) 3. Treatment If you have contacted your water supplier and followed its instructions and you are still having problems, you need to increase the frequency of applications of low-foaming detergent/bleach starting from bi-monthly purging down to using it every other day as required to eliminate your particular problem.
LuxeAir Series Owner's Manual & Installation Guide WHIRLPOOL USER INFORMATION PLEASE NOTE: The whirlpool action may cause even small amounts of bubble bath or shampoo to foam excessively. Exercise moderation in experimenting with different soap products. No servicing of this product should be done by the user. There are no user serviceable parts. All controls are located in the control recesses on the lip of the tub. These are the only controls that should be used by the consumer.
LuxeAir Series Owner's Manual & Installation Guide TROUBLESHOOTING GUIDE WARNING: Always turn off power at the main electrical service panel when servicing your whirlpool. SYMPTOMS POSSIBLE PROBLEMS SUGGESTED SOLUTIONS Motor does not start 1) 2) 3) 4) 5) 6) 7) 1) 2) 3) 4) 5) 6) 7) Motor does not reach full speed 1) Low voltage. 2) Motor windings connected for wrong voltage. 3) Wiring too small. 1) Contact your electrician. 2) Contact Aquatic. 3) Contact your electrician.
LuxeAir Series Owner's Manual & Installation Guide REPLACEMENT PARTS ORDER FORM FOR LUXEAIR SERIES How To Use: 1. Find your part on the map and make note of its number & letter. 2. Using map number and letter, choose part number and select color (or finish) on Parts List provided on pages 28-29. 3. Fill out the form below with the selected information. Fax or send to Aquatic. 4. Call Aquatic for parts pricing and shipping charges.
LuxeAir Series Owner's Manual & Installation Guide LUXEAIR SERIES REPLACEMENT PARTS MAP 1. 1b. 2. 1a. 2a. 3a. Pump and Blower Control 2c. 2a. 8184ROTxx (StressEaz jet) 2b. 8184JTB (StressEaz jet body) 2c. 8180NUT (StressEaz nut) 1a. 8186ASSYxx (Full size directional jet) 1b. 8186VJTB (V-jet body) 8186BDY (90 degree jet body) 8186WFTG (Wall fitting) 3. 2b. 3b. Pump Control (with chromatherapy option) 3c. Airbath Control (with chromatherapy option) 3a.
LuxeAir Series Owner's Manual & Installation Guide LUXEAIR SERIES REPLACEMENT PARTS MAP 4. 8. 1102 (Blower control box – NO Chromatherapy option) 1103 (pump control box – NO Chromatherapy option) 8075BOX (Blower control box – WITH Chromatherapy option) 100820 (Pump control box – WITH Chromatherapy option) 9. 8095HEATER (Inline Maintenance heater) 5. 10. 8000BLW (Blower – WITH Chromatherapy option) 8150UNION (1.5” Pump unionincluding O-ring) 1104BLOWER (Blower – NO Chromatherapy option) 11.
LuxeAir Series Owner's Manual & Installation Guide Aquatic Limited Lifetime Warranty FOR MILLENNIUM, INFINITY AND LUXEAIR SERIES WHIRLPOOLS, SERENITY AIR BATHS, SERENITY STUDIO, HOTSOAK SERIES BATHS AND RESTORATION SERIES Limited Warranty For Original Consumer For Household Usage WHAT PRODUCTS ARE COVERED Structures and surface finishes, pumps and blowers on the Millennium, Infinity, LuxeAir, Serenity Air Baths, Serenity Studio, HotSoak, and Restoration Series.
AQUATIC Fax-On-Demand System: Toll Free (877) 618-7024 8101 E. Kaiser Blvd. • Anaheim, CA 92808 (800) 945-2726 • Fax (866) 544-5353 • www.aquaticbath.com 8MANLUX | F.O.D.