SERENITY SERIES Owner’s Manual & Installation Guide Note: Read all instructions before proceeding with installation. All specifications are ± 1/4’’ and are subject to change without notice.
TABLE OF CONTENTS 2 Product Registration information Congratulations! Safety Instructions 3 4 5 Installation Instructions Pre-Installation Procedures Structural Preparation Factory Installed Tile Flange Plumbing Rough-In Measurements Electrical Installation Chromatherapy LED Lighting Variable Speed Air Blower Remote Mounting Installation Instructions for Freestanding Models Variable Speed Air Blower Remote Mounting for Freestanding Models Serenity 27 Installation and Maintenance Instructions 6
Aquatic Product Registration Information Your product warranty is registered and confirmed with Aquatic through the Serial Number on your unit. You do not need to contact Aquatic to confirm registration. Please fill out the information below and reference when contacting the distributor to expedite warranty claims. Owner Information: Model Name Serial Number (See Table of Contents for Location) Purchase Date Distributor 8101 E. Kaiser Blvd. • Anaheim, CA 92808 (800) 877-2005 • Fax (714) 998-5340 www.
congratulations! You have chosen one of the finest bath products in the world! Aquatic supports your purchase with strong commitments to quality and customer satisfaction. Please read and follow all of the instructions contained in this Owner’s Manual before installing, operating or maintaining your air bath. In addition, you should continually refer to these instructions during the life of your air bath. Failure to comply with these instructions may invalidate your warranty.
IMPORTANT SAFETY INSTRUCTIONS warning: when using this unit, these basic precautions should be followed. This manual contains information and instructions for proper operation and maintenance of your air bath. Failure to follow these instructions could result in personal injury, electrical shock or fire. READ AND FOLLOW ALL INSTRUCTIONS danger! To reduce the risk of injury: 1. Do not permit children to use this unit unless they are closely supervised by an adult at all times.
INSTALLATION INSTRUCTION GUIDELINES READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION PRE-INSTALLATION PROCEDURES: please note: the manufacturer accepts a 1/4” variance. there are variations on each tub and specifications are subject to change as we improve upon our product as required. the dimensions needed for site preparation and structure buildings should be measured from the tub; Aquatic assumes no responsibility for preparatory work.
INSTALLATION INSTRUCTION GUIDELINES READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION QUIETNESS OF OPERATION: Aquatic has engineered their air baths from base to lip to ensure quality, value, functional design, and maximum bathing comfort. However, installation is accountable for as much as 50% of a tub’s operating quietness. Please ensure the following: • The floor structure is adequate to support the installation.
INSTALLATION INSTRUCTIONS STRUCTURAL PREPARATION: 5. When placing the tub on a platform or cut out (see Diagrams 1A and 1D), the opening should be 1” smaller than the specified rim dimensions. Extreme care must be taken in this type of installation to ensure the tub will come to rest entirely on the base. 1A 1B 1C 1D *Does not apply to freestanding models. WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LOCALLY LICENSED ELECTRICIAN. 6. Another installation option is that of a tile flange.
INSTALLATION INSTRUCTIONS plumbing: 1. After securing tub in place, normal waste and overflow, water spout and valves are installed per normal plumbing procedures, in accordance with all state and local standards. 2. Install standard 1-1/2” trap to drain and overflow. Before proceeding, make final operational check by filling tub with water to overflow and operate blower for 5 minutes. Carefully check for leaks both while blower is running and after it has been turned off.
INSTALLATION INSTRUCTIONS Rough-In Measurements: MODEL A From center of overflow pipe to outside rim B A 6A From center of drain to tub rim Serenity 1 6 1/4" 13" Serenity 2 5 3/4" 13 1/4" Serenity 3 1 1/2" 10 1/2" Serenity 4 1 1/2" 10 1/4" Serenity 5 1 3/4" 10" Serenity 6 5 1/2" 14 1/4" Serenity 7 2 1/4" 9 3/4" Serenity Studio 8 2 1/2" 14" Serenity Studio 9 2 1/2" 13" Serenity 10 4 3/4" 12 1/8" Serenity 11 4 3/4" 12 1/8" Serenity Studio 12 4 3/4" 12 1/8" Serenity
INSTALLATION INSTRUCTIONS electrical installation: WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRICIAN, IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES. WARNING: When using electrical products, precautions should always be followed, including the following: DANGER: RISK OF ELECTRIC SHOCK! This unit requires one dedicated circuit, protected by a Ground Fault Circuit Interrupter (GFCI).
INSTALLATION INSTRUCTIONS Chromatherapy LED lighting: All Serenity models* come equipped with a digital color-changing underwater light for soothing chromatherapy. To complement your bathing experience, the Aquatic electronic control panel allows you to select a color according to the desired effects. To Turn Your Chromatherapy Lighting System ON: Press the light button once to turn the Chromatherapy Light on in color wash mode. A second press of the button will turn the lighting system off.
INSTALLATION INSTRUCTIONS Variable Speed Air Blower Remote mounting All models except freestanding models Relocating the Variable Speed Air Blower: All electrical connections should be done by a licensed electrician. The blower and controls are installed at the factory. If you wish to install the blower for a more convenient access, please follow the instructions provided below.
INSTALLATION INSTRUCTIONS installation of freestanding models: 9A NOTE: • • • Freestanding units must be placed on a perfectly leveled floor. The blower must be mounted in a remote location and cannot be installed on the bath (see pages 17 and 18). Wall mounted or freestanding faucets must be used. 22 1/2” Serenity 10 & 37 Installation: For information on electrical installation, maintenance and care, troubleshooting and warranty, please refer to the Table of Contents.
INSTALLATION INSTRUCTIONS Serenity 11 & 13 Installation: Anchor Pin Holes 10A Before the floor installation is complete, make sure the floor is level. Once the floor installation is complete, determine the exact location of the bath and trace the contour of the bath with an erasable marker pen. For information on electrical installation, maintenance and care, troubleshooting and warranty, please refer to the Table of Contents. 20” 20 1/2” 17 1/4” 1.
INSTALLATION INSTRUCTIONS Serenity STUDIO 17, 23, 24, 25 and 26 Installation: Before the floor installation is complete, make sure the floor is level. Once the floor installation is complete, determine the exact location of the bath and trace the contour of the bath with an erasable marker pen. For information on electrical installation, maintenance and care, troubleshooting and warranty, please refer to the Table of Contents. 1.
INSTALLATION INSTRUCTIONS Serenity STUDIO 17, 23, 24, 25 and 26 Installation (Cont): 2. Drill 2” holes for the drain and air passage holes. To prevent the bath from moving sideways, secure the two anchoring pins (3/8” x 3” lag bolts) to the floor (see Diagram 10F). Leave the lag bolts 1 1/2” above floor. Wipe off the marker tracings. 10G 3. Install the overflow and drain on the bath. Cut pipes to desired length prior to assembly (see Diagram 10G).
INSTALLATION INSTRUCTIONS Serenity 10 & 37 Key Pad Infrared Sensor Flow Blower Control Box One Way Valve Serenity Freestanding model Control Box Wiring To 120 vac minimum 15 amp dedicated GFCI protected circuit To Blower To Key Pad Control Box To IR Sensor Not Used Not Used Key Pad Infrared Sensor Flow Blower 18 One Way Valve Aquatic
INSTALLATION INSTRUCTIONS Serenity 11, 13, 17, 23, 24, 25 and 26 Key Pad Infrared Sensor Flow Blower Control Box One Way Valve Serenity freestanding model Control Box Wiring To 120 vac minimum 15 amp dedicated GFCI protected circuit To Blower To Key Pad Control Box To IR Sensor Not Used Not Used Key Pad Infrared Sensor Flow Blower Aquatic One Way Valve 19
INSTALLATION INSTRUCTIONS Serenity 27 Copper Air Bath Serenity STUDIO 27 Installation: Before the floor installation is complete, make sure the floor is level. Once the floor installation is complete, determine the exact location of the bath and trace the contour of the bath with an erasable marker pen. BOTTOM VIEW For information on electrical installation, maintenance and care, troubleshooting and warranty, please refer to the Table of Contents. 1.
INSTALLATION INSTRUCTIONS Serenity 27 Copper Air Bath The Hartford loop can be installed in or on a wall (see directions) anchored to a 2x4. Install so that two inches of loop is above the bottom of the overflow hole.
MAINTENANCE and care Serenity 27 Copper Air Bath CLEANING: · · · · · · · · Wash with soap that has low acidic content (anything with acid will act as a polisher), water, and a NON ABRASIVE cloth or sponge. NEVER USE anything abrasive, such as Soft Scrub, Clorox or Drano type products. DO NOT use a copper polish. You will ruin the tub’s finish. DO NOT use Flitz Faucet and Fixture Wax. This product will ruin the finish.
operation of SERENITY AIR BATHS BATHside CONTROL SYSTEMS: Electronic Control Panel (see Diagram 11A): 1. To Turn Air Bath System On: Pressing the on/off button will turn the blower on in “constant mode.” The light indicator will illuminate when the system is on. The blower and the heater will automatically shut off after a 20-minute period. On/Off Button Indicator Light Mode Key Decrease Speed Increase Speed Chromatherapy Light (not included on freestanding models) 2.
operation of SERENITY AIR BATHS Purge 24 Hours: It is possible for the user to program a purge cycle that will start every day for a duration of 1 minute. Aquatic strongly recommends activating this feature. The purge cycle will help ensure that the air channels stay dry even when you have taken a soaking bath or shower. To activate this purge feature, the user must hold down the “+” button for 5 seconds when the blower/heater is off or waiting for the normal purge.
operation of SERENITY AIR BATHS remote control operation: To Turn Air Bath On: Pressing the on/off button will turn the blower on in “constant mode”. Once the blower is on, pressing a second time will turn the blower off. The blower will shut off after a 20-minute period. To Change Modes: Pressing the mode button alternates the blower modes of operation from constant mode to wave mode and then to pulse mode.
MAINTENANCE and care CLEANING: Use common household, non abrasive cleaners for most cleaning jobs. Clean grease, oil, paint and ink stains with Isopropyl (rubbing) alcohol. Rinse well and dry with a clean cloth or sponge. Do not run the air system with foaming cleaners or soaps. Rinse the bath thoroughly after cleaning.
SERENITY AIR BATHS user information Please note: The air bath action may cause even small amounts of bubble bath or shampoo to foam excessively. Exercise moderation in experimenting with different soap products. No servicing of this product should be done by the user. There are no user serviceable parts. All controls are located in the control recesses on the lip of the tub. These are the only controls that should be used by the consumer.
troubleshooting guide warning: Always turn off power at the main electrical service panel when servicing your air bath. symptoms Air Bath does not operate. possible problems 1) No power to Air Bath unit. 1) 2) 3) Blower Control Box is not plugged in. Control Panel connector to controller box is disconnected. Blower Motor is disconnected from control box. 2) 3) Reset circuit breakers and GFCI if tripped. Check fuses and replace if bad. Make sure plug is fully inserted into the outlet.
SERENITY AIR BATHS replacement parts list description 1) 2) 3) 4) Air Blower Control Box Check Valve Control Panel 5) 6) 7) 8) Light Wall Fitting (incl.
Replacement parts Order form for Serenity Air Baths How To Use: 1. Find your part on the map and make note of its number and letter. 2. Using map number and letter, choose part number and select color (or finish) on parts list provided on page 29. 3. Fill out the form below with the selected information. Fax or send to Aquatic. 4. Call Aquatic for parts pricing and shipping charges.
Aquatic Limited Lifetime Warranty For Millennium, Infinity, Century, LuxeAir, Luxury, Serenity Air Baths, Serenity Studio, HotSoak and Restoration Series Limited Warranty For Original Consumer For Household Usage WHAT PRODUCTS ARE COVERED Structures and surface finishes, pumps and blowers on the Millennium, Infinity, Century, LuxeAir, Luxury, Serenity Air Baths, Serenity Studio, HotSoak, and Restoration Series.
AQUATIC Fax-On-Demand System: Toll Free (877) 618-7024 8101 E. Kaiser Blvd. • Anaheim, CA 92808 (800) 877-2005 • Fax (714) 998-5340 • www.aquaticbath.