Installation manual

Villager Esprit Stove 16
INSTALLATION
Fitting of the EGD ( Exhaust Gas Diversion) Style Throat Plate & Liners
The 6 and 10kw models of the Esprit stove is
supplied with the EGD style throat plate ( See fig. a )
not the standard style as supplied with the 4 and 8kw
stoves.
The liner set is installed first as follows:-
Open the main fire door.
Remove the fuel retainer, by lifting both ends
free of the side landings and diagonally
rotating the part through the door aperture.
Insert the side liner panels, these go in behind
the rear liner(s) ends and the ends of the
tertiary air bar, one each side of the stove.
(See Fig. b)
Set the small liner(s) into the back of the
firebox, below the tertiary air bar. These also
retain the side liners in position.
Insert the EGD throat plate into the stove and
manoeuvre into position with the location lugs
sit onto the tertiary air bar location holes and
the liner retaining tab against the rear liner(s)
(See fig. c)
Allow the EGD throat plate to drop forward to
rest on the air wash inner cover (within the
inside of the stove body) at the top of the
stove. See fig c cut away drawing.
Replace front fuel retainer.
Fig. a
Tertiary Air Bar
Side Liner
Rear
Liner(s)
Fig. b
Location lugs to sit in tertiary
air bar location holes
Rear liner retaining tab
Fig. c
EGD in correct position resting
on inner airwash cover