Installation manual

FINAL CHECK LIST
Before handing over the installation to the
customer it is requirement under Document J the
appliance is lit and the functioning of the chimney
system is checked for satisfactory operation.
Be sure that the chimney is operating and
ALL smoke and fumes are vented to the
atmosphere through the chimney
terminal.
Check all joints and seals.
Clean the outside of the appliance to
prevent any stains becoming burnt on.
Check the flue draught which should read
1 - 2mm water gauge, or 0.1- 0.2 mbar.
If Building Control Consent route is being
sought please complete the check list on
page 18.
For a registered Competent Persons
Scheme, such as HETAS, please
complete the Certificate Of Compliance,
which is used for checking and reporting
the installation as imposed by the
Government
Explain the controls and operation of the
appliance to the customer.
The following details must be checked and
completed in full by the installer at the time of
installation. Please answer all questions as fully as
possible.
Arada Ltd cannot be held responsible for the
chimney or installation problems.
17 Villager Esprit Stove
INSTALLATION
ADJUSTING THE SELF
LEVELLING FEET
The Villager Esprit stove is equipped with
adjustable rear levelling feet, these are ideal for
use, where the hearth surface is not flat or level.
Adjustment is as follows :
Position the stove on the hearth into its final
resting place, ensuring room for the flue
connections etc.
On the rear leg of the stove, loosen the pozi
screw, and rotate the inner „cam‟ shaped
levelling foot until this touches the hearth.
(see fig. 10.)
Re-tighten the pozi screw. Check the stove is
level with a spirit level.
Repeat for the other rear leg.
Fig. 10. Adjusting The Rear Feet