Specifications
Clearance
each end
Fig.12
When using the Mortar Plunge blades, the cut
should have enough clearance on each end
(shown in fig:12), to ensure that no hammering of
the blade ends occurs (as shown in fig.13).
“Hammering!”
Fig.13
7. MAINTENANCE
WARNING: To reduce the risk of serious
personal injury, turn the tool off and disconnect
tool from the power source before making any
adjustments or removing/installing attachments
or accessories.
Before reconnecting the tool, depress and release
the trigger switch to ensure that the tool is turned
off.
To assure product SAFETY and RELIABILITY,
repairs, maintenance and adjustment (including
brush inspection and replacement) should be
performed by an ARBORTECH authorised service
center. Always use identical replacement parts.
7.1 Motor
Cleaning
CAUTION: Blowing dust and grit out of the
motor and switch actuator using clean,
dry compressed air is a necessary regular
maintenance procedure. Dust and grit particles
often accumulate on interior surfaces and can
cause premature failure. Not regularly cleaning
the AS170 will affect the tools warranty.
CAUTION: ALWAYS WEAR SAFETY GLASSES
when using or cleaning this tool.
Never use solvents or other harsh chemicals for
cleaning the non-metallic parts of the tool. Use a
clean, dry cloth only.
Lubrication
ARBORTECH tools are properly lubricated at the
factory and are ready for use.
Accessories
To reduce the risk of injury, only ARBORTECH,
accessories should be used with this product.
Recommended accessories for use with your tool
are available at extra cost from your local dealer or
authorised service center.
Repairs
If you need any assistance in locating any
accessory, or general tool query please contact
ARBORTECH. www.arbortechusa.com or free call
866-517-7869.
Brushes
The AS170 is fitted with Auto-cut off brushes. When
the brushes are worn below minimum length they
stop tool operation reducing internal motor damage.
Contact your local dealer or authorised service
center for brush replacement.
7.2 V Belt and Pulleys
CAUTION: The V-Belt should be re-tensioned
after the first 5 hours of use.
To access these items, remove the 4 screws holding
the plastic cover on the right side of the tool (see
fig.14). Inspect the belt for correct tension and signs
of damage. If tensioning is required, loosen the the
tension idler nut (one turn only). Slide the tension
idler outward to increase the tension to the value
noted in the General Specifications in Section
3 and re-tighten. If belt replacement is required,
loosen the tensioner idler, replace the belt and re-
tension the idler as specified.