4.1.7. Transmitter Access Card (TAC) Settings
Follow the instruction below on how to program the TAC into the transmitter. The infrared IR
programmer unit is required to complete the programming. Please contact ARC representative
for more details.
1) Rotate the power switch key to OFF ( 0 ) position.
2) With the STOP button elevated, press and hold PB1, PB2,
PB3 and PB4 at the same time.
3) Rotate the power switch key to ON ( I ) position.
4) Let go PB1, PB2, PB3 and PB4 at the same time, the Status
LED displays orange fast blinks (entered TAC mode).
5) Placed the access card over the RFID marking located on the
backside of the transmitter.
6) Status LED with 1 second green means the access card is being programmed into
the transmitter.
7) Status LED with 1 second orange means the access card is already programmed
into the transmitter.
8) Status LED with 1 second red means unable to store any more access cards. Each
transmitter can only store up to 16 access cards.
9) Use the infrared IR programmer unit to extract all access card information stored
inside the transmitter for further programming. Other than restricting any
unauthorized personnel from using the transmitter, it can also be individually
programmed unlocking any specific function or functions on the transmitter allowing
a more experienced or qualified user to operate, such as the magnet lift, tandem
operation, entering restricted areas, etc
10) Exit TAC mode by rotate the power switch key to OFF ( 0 ) position.