5. Operating Procedures
5.1 General Operation
a. Reset the STOP button located on the top left-hand corner of
the transmitter by rotating it clockwise or counter clockwise, the
button will pop up. Transmitter is powered on when the STOP
button is elevated.
b. After turning on the transmitter power, check the Status LED on
the transmitter for any sign of system irregularities (refer to
section 6.3.1 Transmitter Status Indications). If the transmitter
is in good working order the Status LED will display constant
green for up to 2 seconds at power on (no faults detected).
c. Press and hold both PB1 & PB2 pushbuttons at the same
time for up to 1 second to activate the receiver MAIN relays
(Status LED constant green). When the receiver MAIN
relays are activated the Status LED will change from
constant green to constant orange (system on). Then
press any pushbutton on the transmitter to begin operation.
Pressing any pushbutton prior to executing the START
command at startup will result in no signals transmitted
(Status LED blinks orange). Refer to section 4.1.4 Start
Function Settings to cancel START activation.
d. In case of an emergency, press down the STOP button to disconnect the receiver
MAIN relays and the transmitter power (Status LED blinks 3 reds and then shuts
off). To resume operation, rotate the STOP button clockwise or counter clockwise,
the button will pop up. Then press and hold both PB1 & PB2 pushbuttons at the
same time for up to 1 second to reconnect the receiver MAIN relays. Refer to
section 4.1.4 Start Function Settings to cancel START activation.
e. After 5 or 30 minutes of inactivity (pushbutton not pressed) the receiver MAIN relays
are temporarily disconnected (refer to section 4.1.5 Inactivity Timer Settings). The
Status LED blinks 3 reds and then shuts off. Press any pushbutton to resume
operation (refer to section 4.1.4 Start Function Settings).
P
RESS