Instruction Manual

Flex 12HRX/8HRX Standard, AB and Tandem Instruction Manual (FCC/CE)
September 2016
Page 13 of 43
4.1.1.7. Toggled Contact
When pushbutton is released the corresponding output will maintained contact or
closure until next time the user presses the same pushbutton again. This type of
action usually applies to external application such as lights. Refer to section 4.2.3.2
on how to set to this function.
4.1.2. Voltage Settings
Prior to installation always check the voltage setting is correct for your application.
12-24VDC
4.1.3. Indicator Light and Buzzer Installation
The miniature indicator light and buzzer can be easily
fitted onto the receiver enclosure. The indicator light
or the buzzer works simultaneously with the receiver
MAIN output(manufacture preset). When receiver
MAIN output are activated the indicator light or the
buzzer is also activated, or vise versa. Make sure the
indicator light or the buzzer is connected to the
Function3 output CN8 port located on the IO board
inside the receiver. Please contact ARC
representative if you would like the indicator light or
the buzzer work differently than described above.
4.1.4. Other Function Output Settings
Listed below are other types of functions that can be outputted through the three Function output
(OUT5,OUT6,CN8) via the infrared IR programmer unit. Please contact ARC representative for
more details.
LV → Function output closes when receiver voltage is low.
ID → Function output works simultaneously with all motion commands.
NORMAL → START function + AUX with normal momentary output.
TOGGLE → START function + AUX with toggled/latching output.
TOG&E → START function + AUX with toggled/latching output. The output opens when STOP button
is pressed down and transmitter power off.
S/P Function output closes when START command is executed and
opens only when transmitter power is turned off.
EXT → Function output works simultaneously with the receiver MAIN output.
TDM A+B → Function output closes when selector switch is rotated to the A+B position and opens when
rotate to A or B positions (tandem monitoring output).
HORN → Function output closes for up to 3 seconds when START command is executed at transmitter
power on and then becomes a normal momentary output thereafter.
G SENSOR → Function output closes when Zero-G sensor is triggered (receiver MAIN output deactivated)
and opens when receiver MAIN output are reactivated.