Owner's Manual

Table Of Contents
26
Setup (0x27)
Starts remote setup of the unit.
COMMAND:
Byte: Description:
St 0x21
Zn 0x01
Cc 0x27
Dl 0x01
Data1 0xF0
Et 0x0D
RESPONSE:
Byte: Description:
St 0x21
Zn Zone Number
Cc 0x27
Ac Answer code
Dl 0x01
Data1 0xnn - setup mode active, nn = version of menu
0xFF - setup mode from front panel, remote setup not possible
Et 0x0D
Room EQ name(s) (0x34)
Request Room EQ name(s).
COMMAND:
Byte: Description:
St 0x21
Zn 0x01
Cc 0x34
Dl 0x01
Data1 0xF0 - request EQ names
Et 0x0D
RESPONSE:
Byte: Description:
St 0x21
Zn Zone Number
Cc 0x34
Ac Answer code
Dl 0xn - dependant on number of EQ slots filled, 20, 40, 60
Data1-20
Data21-40
Data41-60
EQ1 name (read only / 20 characters)
name in ASCII characters
EQ2 name (read only / 20 characters)
name in ASCII characters
EQ3 name (read only / 20 characters)
name in ASCII characters
Et 0x0D