Owner's Manual
Table Of Contents
- Handbook
- Factory default reset
- Safety Guidelines
- Welcome
- Contents
- Before You Begin
- Trademark Acknowledgments
- Rear Panel Connections and Controls
- Audio/Video Connections
- Connection Guide
- Radio & Wireless Audio Connectors
- Other Connectors
- Speakers
- Connecting Speakers
- Operation
- Extended front panel menu
- Front Panel Operation
- Remote Control
- Device Mode/Source keys
- Customising the Remote
- Essential Setup
- Auto Speaker Setup
- Setup Menus
- Connecting to a Network
- Decoding Modes
- Tuner Operation
- Troubleshooting
- Specifications
- Device Code Tables
- Custom Installation Notes
- Contents
- Introduction
- Set-up
- Conventions
- Serial Cable Specification
- Example command and response sequence
- System Command Specifications
- Input Command Specifications
- Output Command Specifications
- Menu Command Specifications
- Setup Adjustment Command Specifications
- Treble Equalisation (0x35)
- Bass Equalisation (0x36)
- Room Equalisation (0x37)
- Dolby Volume (0x38)
- Dolby Leveller (0x39)
- Dolby Volume Calibration Offset (0x3A)
- Balance (0x3B)
- Subwoofer Trim (0x3F)
- Lipsync Delay (0x40)
- Compression (0x41)
- Request incoming video parameters (0x42)
- Request incoming audio format (0x43)
- Request incoming audio sample rate (0x44)
- Set/Request Sub Stereo Trim (0x45)
- Set/Request Zone 1 OSD on/off (0x4E)
- Set/Request Video Output Switching (0x4F)
- Set/request input name (0x20)
- FM Scan up/down (0x23)
- DAB Scan (0x24)
- Heartbeat (0x25)
- Reboot (0x26)
- Bluetooth status (0x50)
- Setup (0x27)
- Room EQ name(s) (0x34)
- Now Playing Information (0x64)
- Input config (0x28)
- General Setup (0x29)
- Speaker Types (0x2A)
- Speaker Distances (0x2B)
- Speaker Levels (0x2C)
- Video Inputs (0x2D)
- HDMI settings (0x2E)
- Zone settings (0x2F)
- Network (0x30)
- Bluetooth (0x32)
- Engineering menu (0x33)
- AV RC5 command codes
- Product Info
- Mandatory Software Update
- Software Release Notes
- Warranty & Product Registration
38
Engineering menu (0x33)
Set / request Engineering menu info.
COMMAND:
Byte: Description:
St 0x21
Zn 0x01
Cc 0x33
Dl 0x01 / 0x30
Data1
Data 1-
0xF0 - request Engineering menu settings
set Engineering menu settings as below
Et 0x0D
RESPONSE:
Byte: Description:
St 0x21
Zn Zone Number
Cc 0x33
Ac Answer code
Dl 0x2B
Data1
Data2
Data3
Data4
Data5
Data6
Data7-10
Data11
Data12
Data13
Data14
Data15
Data16
Data17
Data18-26
Data27-30
Data31-34
Data35-48
Reset Factory Defaults (set only)
0x00 - no effect
0x01 - Reset factory defaults
Check for update (set only)
0x00 - no effect
0x01 - Check for Update
Restore Secure backup
0x00 - no effect
0x01 - Restore secure backup
Store Secure Backup
0x00 - no effect
0x01 - Store secure backup
Restore USB backup
0x00 - no effect
0x01 - Restore USB backup
Store USB Backup
0x00 - no effect
0x01 - Store USB
Pin in hex 1-4
Region
0x00 - Europe
0x01 - US
0x02 - Canada
0x03 - Australia
0x04 - China
Remote Code
0x00 - 16
0x01 - 19
Standby Mode
0x00 - Auto
0x01 - Manual
Protection sensitivity
0x00 - High (default)
0x01 - Medium
0x02 - Low
Use Display HDMI
0x00 - Yes
0x01 - No
Display type
0x00 - 16:9
0x01 - 21:9
Shut down code (info only)
0x00 - 00 (normal)
0x01 - 01 (amp DC offset)
0x02 - 02 (amp overtemp)
0x03 - 03 (amp overcurrent)
Host/IAP version (info only)
Version in ASCII e.g. “2.01/0.03”
DSP version (info only)
Version in ASCII e.g. “1.03”
OSD version (info only)
Version in ASCII e.g. “0.11”
NET version (info only)
Version in ASCII e.g. “2.5.13.50017-6”
Et 0x0D