Specifications
Chalet 1800 Ins 21
TROUBLESHOOTING
PROBLEM CAUSE CURE
Glass is Dirty 1. Wood is wet Use dry wood
2. Turning down air control or
damper too soon
Do not turn down until:
❖ there is a good bed of coals
❖ the wood is charred
3. Draft too low – Improper
chimney height and / or di-
ameter
❖ Chimney plugged or restricted,
check flue
❖ Provide outside air for combus-
tion
4. Door gasket leakage
❖ Replace gasket
❖ Check latch
5. Excessive Creosote Buildup
See 1,2,3, above
Low Heat Output
1. Wood is wet Use dry wood
2. Fire too small Build a larger fire
3. Draft too low Chimney plugged or restricted,
inspect and clean
Will not burn Overnight
1. Air control is set too high Set control lower
2. Not enough wood Un-split wood is preferred for over-
night burns
3. Draft too high Excessive chimney height or small
diameter
Cannot establish proper burn
1. Combustion air supply
blocked
❖ Ensure adequate air is avail-
able for combustion
2. Draft too low
❖ Chimney liner plugged or
restricted, inspect and clean
❖ Chimney liner oversized or
otherwise unsuitable