Specifications

Chalet 1800 Ins 5
SAFETY NOTE: If this insert is not properly installed, a
house fire may result. For your safety, follow the installation
instructions. Contact your local building or fire officials, or
any other authority having jurisdiction about restrictions and
permit/inspection requirements in your area.
WHEN LOCATING YOUR INSERT: Consider safety and
the fact that the insert will need a chimney. It is a good idea
to plan your installation on paper, using exact measure-
ments for clearances and floor protection before actually
beginning the installation.
These installation instructions describe the installation and
operation of the Archgard CHALET 1800 WOOD Fire-
place Insert. This insert meets the U.S. Environmental Pro-
tection Agency’s 1990 particulate emission standards. It is
also listed by Warnock Hersey Test Laboratories, Inc. to UL
Safety Standard 1482 and ULC S628. It also meets the re-
quirements of (UM) 84-HUD.
SAFETY LABEL
A copy of the label that accompanies each Archgard Chalet
1800 WOOD Fireplace Insert , is printed here for your con-
venience.
NOTE: Archgard units are constantly being improved. If
there is a conflict between the label on the unit and the one
printed here, the label on the unit is the correct one. The
safety label is attached to the side of the unit.
YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
LISTED FACTORY BUILT FIREPLACE IN-
SERT
CERTIFIED FOR USE IN CANADA AND
U.S.A
DO NOT REMOVE THIS
JAN
FEB
MAR
APR
MAY
JUN
DEC
NOV
OCT
SEPT
AUG
JUL
2006 2007 2008
UNITED STATES ENVIRONMENTAL PROTECTION AGENCYCERTIFIED TO
COMPLY WITH JULY 1999, PARTICULATE EMMISSIONS STANDARDS.
SERIAL # XXXXX
HOT WHILE IN
OPERATION. DO
NOT TOUCH. KEEP
CHILDREN, CLOTH-
ING AND FURNI-
TURE AWAY.
CONTACT MAY
CAUTION
INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS. INSTAL AND USE ONLY IN
MASONARY FIREPLACE. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM
.COMPONENTS REQUIRED FOR INSTALLATION: FAN KIT(FK-1800INS) ELECTRICAL RATING: 1AMP, 60Hz, 120VOLTS 6 “/150MM STAINLESS STEEL LINER. DAN-
GER, RISK OF ELECTRIC SHOCK, DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR INFRONT OF APPLIANCE. DO NOT
REMOVE BRICKS OR MORTOR IN MASONARY FIREPLACE. FOR USE WITH SOLID FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD DIRECLT
ON HEARTH. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS CLOSED, OPEN DOOR TO FEED FIRE ONLY. REPLACE GLASS WITH 5MM
CERAMIC ONLY. INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDTIONS OF USE CREOSOTE BUILD UP MAY OCCUR RAPIDLY. DO NOT
OVERFIRE, IF INSERT GLOWS, YOU ARE OVERFIRING.
303-0144
B
A
C
E
D
Side Wall to Insert=
A
Top of Insert to Bottom
of Mantle (Depth)=B
Side of Insert to
Mantle Leg=C
Hearth Extension
Front=D
Hearth Extension Side
=E
16.25”/412.75 mm 6” = 26”/660mm
8” = 28”/711mm
12” = 32”/813mm
8.75”/222mm Canada=18”/450mm
USA= 16”/400,\mm
Canada = 8”/200mm
USA = 8”/200mm
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH, COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE
This unit has been approved for use in
Washington State ,USA.