User Manual

User's Manual
16
<automode> 0/1 Automode disabled/enabled
<min_rate> minimum rate for connection. If lower than the actual minimum rate for the
selected modulation, the actual lowest supported rate will be taken.
<max_rate> maximum rate for connection. If higher than the actual maximum rate for the
selected modulation, the actual highest supported rate will be taken.
Table 2 - +MS command parameters
<mod>Modulation Possible rates
22 V.22 1200
122 V.22bis 2400,1200
32 V.32 9600, 4800
132 V.32bis 14400, 12000, 9600, 7200, 4800
34 V.34 33600, 31200, 28800, 26400, 24000,
21600, 19200,16800, 14400, 12000,
9600
56 K56Flex 32000,34000,36000 ..... ,56000
90 V.90 29333, 30666,32000 .....,56000
212 Bell 212 1200
103 Bell 103 300
Examples:
AT+MS=34,0,4800,33600 V.34, No Automode, Min. speed 4800, Max speed 33600
AT+MS=,1 Automode
AT+MS=32,1,,14400 V.32 Automode, Max speed 14400 (min speed as before)
Factory Settings: 90,1,300,56000
The requested modulation scheme will be written to S32
The requested min rate will be written to S33
The requested max rate will be written to S34
The actual rate may be read from S35
The actual modulation scheme may be read from S37
(The codes as specified in the Xn command)
Other derivatives of the +MS command:
AT+MS? report current MS settings (e.g. 34,1,9600,33600)
AT+MS=? list the supported values +MS:(22,122.....), (0,1), (300-33600), (300-33600)
Result codes:
OK Syntax OK
Error Otherwise
Related S-Reg: S31-S37