User Manual

User's Manual
17
AT+F Commands - Fax Support
+FCLASS
=<value>
Sets Data/Fax Class1/Voice (0,1,8) mode.
+FCLASS=<value>
[<value> - 0,1,8 (Data/Fax Class1/Voice]
Result codes:
OK Syntax OK
Error Otherwise
+FCLASS? Returns the current setting
Related S-Regs: S32, S150
+FAE Data/Fax Auto Answer
+FAE=<value> [<value> - 0,1 (Data/Fax Class1)]
+FAE? Returns the current setting
Related S-Regs: S151
+FTS=
<value>
Stops transmission and waits.
Terminates transmission and waits for <value>*10ms interval before responding with OK.
ERROR is issued if the modem is on-hook.
+FTS? Returns the current setting
+FRS=
<value>
Receives Silence.
Report back to DTE with OK after <value>*10ms silence interval has been detected. The
command is aborted if any character is received from the DTE (The response will still be
OK). ERROR is issued if modem is on-hook.
+FRS? Returns the current setting
+FTM=
<value>
Transmits data according to the defined modulation. ERROR is issued if modem is on-
hook.
Value Modulation
24 V.27 ter 2400 bps
48 V.27 ter 4800 bps
72 V.29 7200 bps
73 V.17 7200 bps long
74 V.27 7200 bps short
96 V.29 9600 bps
97 V.17 9600 bps long
98 V.17 9600 bps short
121 V.17 12000 bps long
122 V.17 12000 bps short
145 V.17 14400 bps long
146 V.17 14400 bps short
+FTM=? Return 24, 48, 72, 73, 74, 96, 97, 98, 121, 122, 145, 146
+FRM=
<value>
Receives data according to the defined modulation
(See Values above)
ERROR is issued if modem is on-hook.
+FRM=? Return 24, 48, 72, 73, 74, 96, 97, 98, 121, 122, 145, 146
see +FTM