Datasheet
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL FUNCTION ACTUATOR BODY OPTIONS
C 1750 H O - - -
36
toggle
switches
17.5
H
R
The switch is on between centre
terminals (2 & 5) and
the terminals over which the lever
is positioned.
16.4
13.8
C
6.3 x 0.8
H
4.8 x 0.8
K
2.8 x 0.8
T
Solder
X
PCB 0.8 Sq
ACTUATORFUNCTION
Single pole Double pole
TERMINAL
1700 1750
ON - OFF
1710 µ 1760 µ
ON - ON
1720 µ 1770 µ
ON - OFF - ON
1721 µ
ON - OFF -ON
(momentary 1 side)
1722 µ
ON - OFF - ON
(momentary 2 sides)
16(4)A 250Vac T85
UL 20A 250Vac Non Ind (Single pole)
UL 16A 250Vac Non Ind (Double pole)
UL CSA (2 pos types) 250Vac 1hp, 125Vac 1/2hp
UL CSA (3 pos types) 250Vac 1/2hp, 125Vac 1/4hp
CSA 16A 250Vac Non Ind
UL 85˚C, file E45221, CSA file LR10990
UL and CSA N/A on momentary types
Inrush 36A to EN61058-1 & 20A 28Vdc
RoHS compliant
Selective “A, B, C” and “OFF, A, A+B” circuits at 5 amp also available.
3mm contact gap except where marked µ.
Technical data on pages 4 & 5.
9.1
9.1
9.1
2.0
1.2
7.0
Ø2.1
9.1
4.0
12 3
12 3
45 6
In house test
RoHS
1700 & 1750 Toggle Switches 16A 250Vac Single and Double Pole
៉ Nylon toggle switches
៉ Ratings up to 20A,
250V ac
៉ Single and double
pole
៉ Wide choice of
terminals
៉ Choice of circuit
options including 3
position
៉ Flat & round actuator
options
CAT 170 P34-38 0600-3900-1750_2:CAT 170 P34-38 0600/3900/1750 5/11/09 10:20 Page 36