INSTALLATION, OPERATION & MAINTENANCE MANUAL Pizza Prep Tables Sandwich/Salad Units Under-counter Refrigerators and Freezers Worktop Refrigerators and Freezers IMPORTANT Please read this manual completely before attempting to install or operate this equipment.
Installation, Operation & Maintenance Manual TABLE OF CONTENTS SPECIFICATIONS ............................................................................................................................................................................. 3 REGISTRATION ................................................................................................................................................................................ 4 SAFETY INSTRUCTIONS..............................................
UNDER-COUNTER REFRIGERATORS AND FREEZERS SPECIFICATIONS PIZZA PREP TABLES MODEL # V/Hz/Ph AMPS APP-48R 115/60/1 7 APP-71R 115/60/1 7.5 STORAGE CAPACITY PAN 1/3 SHELF CAPACITY HP BTU CHARGE SHIP WEIGHT Cu-ft Size Sq-ft 12 6 22 NEMA PLUG Oz Lbs 16 1/2 5600 9.9 348 5-15P 9 34 1/2 6200 10.
Installation, Operation & Maintenance Manual REGISTRATION The installation date and appliance model must be documented by the end purchaser. . Also, refer to the Warranty section for additional details on registering the appliance.
UNDER-COUNTER REFRIGERATORS AND FREEZERS SAFETY INSTRUCTIONS General Safety WARNING Arctic Air accepts no responsibility for any situation resulting from work carried out in an unprofessional manner, or from the incorrect interpretation or application of regulations. General Installation WARNING Incorrect installation or any modifications made to the appliance may damage property or result in injury or death.
Installation, Operation & Maintenance Manual INTRODUCTION This manual covers the Under-counter Refrigerators and Freezers. Please read this manual completely before attempting to install or operate this equipment. • Confirm that all flooring is structurally strong enough to support the weight of a fully loaded unit; a fully loaded unit can weigh as much as 1500 pounds. Consult with a structural engineer for confirmation if there is any reason to doubt the floor strength.
UNDER-COUNTER REFRIGERATORS AND FREEZERS INSTALLATION Location Electrical connection All units are intended for indoor use only. A fully loaded unit can weigh as much as 1500 pounds. Choose a location with a level floor strong enough to support the total weight of a fully loaded unit. Reinforce the floor if necessary. Refer to the amperage data provided in the SPECIFICATIONS, the serial tag, the local electrical code and/or the National Electrical Code.
Installation, Operation & Maintenance Manual OPERATION Refrigerated Cabinets The internal temperature range for all food prep units, under-counter and worktop refrigerators is 34°F to.38°F.. The internal temperature range for under-counter and worktop freezers is -3°F to -7°F. The rail temperature range for all prep units is 33°F to 41°F. Operate the food prep units only with the pans in place.
UNDER-COUNTER REFRIGERATORS AND FREEZERS Functions Display the set point: Alarm Codes CAUSE OUTPUTS P1 Room probe failure Compressor output according to par Con and COF P2 Evaporator probe failure Defrost end is timed P3 Condenser probe failure Outputs unchanged HA Maximum temperature alarm Outputs unchanged The set point value is displayed and the Compressor LED starts blinking. LA Minimum temperature alarm Outputs unchanged dA Door open Compressor and fans restart 2.
Installation, Operation & Maintenance Manual MAINTENANCE DANGER Turn off the power switch and disconnect the unit from the power source whenever performing service/ maintenance functions and/or cleaning the refrigerated area. Refrigerators and Freezers Clean the interior and exterior using soap and warm water. If this is not sufficient, use ammonia and water or a nonabrasive liquid cleaner. When cleaning the exterior, always rub with the stainless steel grain to avoid marring the finish.
UNDER-COUNTER REFRIGERATORS AND FREEZERS Gasket Maintenance Door Replacement and Adjustment Gaskets require regular cleaning to prevent mold and mildew buildup and to maintain the gasket elasticity. Clean gaskets with warm soapy water. Avoid full strength cleaning products on gaskets, this can cause the gaskets to become brittle and prevent proper sealing. Never use sharp tools or knives, which could tear the gasket and/or rip the bellows, to scrape or clean the gasket. 1.
Installation, Operation & Maintenance Manual WIRING DIAGRAMS Models: APP-48R, APP-71R,AUC-27R,AUC-48R ℃ Models: AST-28R ℃ 12
UNDER-COUNTER REFRIGERATORS AND FREEZERS Models: AST-48R ℃ Models: AUC-27FZ, AUC-48F 13
Installation, Operation & Maintenance Manual Models: APP-48R 14
UNDER-COUNTER REFRIGERATORS AND FREEZERS Models: APP-71R 15
Installation, Operation & Maintenance Manual Models: AST-28R, AUC-27R 16
UNDER-COUNTER REFRIGERATORS AND FREEZERS Models: AST-48R, AUC-48R 17
Installation, Operation & Maintenance Manual Models: AUC-27FZ 18
UNDER-COUNTER REFRIGERATORS AND FREEZERS Models: AUC-48F 19
Installation, Operation & Maintenance Manual ARCTIC AIR WARRANTY One year parts & labor warranty Arctic Air warrants to the original purchaser, all of its new equipment to be free from defects in material or workmanship, under normal use and maintenance service, for a period of one (1) year from the date of original purchase or 15 months after shipment date from the manufacturer, whichever occurs first.
Broich Enterprises, Inc. / Arctic Air Eden Prairie, MN 55344 Phone: 952-941-2270 Fax: 952-941-3066 Website: www.arcticairco.