Dehumidifier Instruction Manual Thank you very much for purchasing our duhumidifier. Before using your duhumidifier, please read this owner's manual carefully and keep it for future reference.
Contents Preparation ---------------------- 2 Safety Precautions ---------------- 4 Cautions ------------------------ 5 Operation ----------------------- 6 Maintenance --------------------- 11 Faults Diagnosis ------------------ 12 Sociable Remark ------------------ 13 1
Preparation control panel handle (both sides) air outlet grille air intake grille panel air filter (behind the grille) drain hose outlet bucket water level window power cord buckle (placed in bucket) pump drain hose outlet (on some models) caster power cord power plug front rear 2
Preparation Accessories:(placed in the bucket of the unit) pump drain hose(1pc) (only for the unit with pump featrue) power cord buckle(1pc) female threaded end(1pc)(on some models) NOTE: The unit you purchased may be look like one of the followings: 3
Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. -Do not exceed the rating of the power outlet or connection -Do not use the unit in small spaces. device. -Do not put in places where water may splash onto the unit. -Do not operate or stop the unit by switching on or off the power. -Place the unit on a level, sturdy section of the floor.
Cautions -This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Operation Smart functions: Place correctly -This unit is designed to operate with a working environment between 5°C(41°F) and 35°C(95°F). -Auto Shut Off When the bucket full indicator light illiminates and the setting humidity is reached, the unit will be shut off automatically. -Wait 3 minutes before resuming operation After the unit has stopped, it can not be restart opertation in the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
Operation NOTE: The control panel of the unit you purchased may be look like one of the followings: Auto defrost Full Full On Off Defrost On Off FILTER button The check filter feature is a reminder to clean the Air Filter for more efficient operation. The Filter light(Clean filter light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the Filter button and the light will go off. PUMP button(optional) Press to activate the pump operation.
Operation Timer Timer button Press to initiate the Auto start and Auto stop feature, in conjuction with the + and — buttons. When the unit is on, first press the Timer button, the Timer Off indicator light illuminates. It indicates the Auto Stop program is initiated. Press it again the Time On indecator light illuminates.It indicates the Auto Start is initiated. When the unit is off, first press the Timer button, the TIMER ON indicator light illuminates. It indicates the Auto Start program is initiated.
Operation LED display Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the actual (±5% accuracy) room % humidity level in a range of 30% RH(Relative Humidity) to 90%RH(Relative Humidity). Error Codes: AS- Humidity sensor error; ES- Temperature sensor error; E3- Unit malfunction; EC- Refrigerant leakage detection malfunction (on some models); Eb- Bucket is removed or not in right position-Replace the bucket in the right position.
Operation Remove the plastic cover by couter-clockwise rotation. Female threaede end Water hose NOTE: The pump operation on light blinks at 1Hz when the pump is operational failure. Please turn off the unit and plug the power cord out. Check the following things: Cleaning the filter of the pump. -Remove the bucket from the unit, take down the pump and clean the filter of the pump. -Check that the pump drain hose does not link or block. -Empty the water of the bucket.
Maintenance Care and cleaning of the dehumidifier WARNING: Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. 1.Clean the bucket Clean the bucket with water every few weeks. 2.Clean the air filter Clean the filter with water at least every 30 days or more often if necessary. CAUTION: DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance. 3.
Faults Diagnosis Please check the machine according to the following form before asking for maintenance: Faults Diagnosis Unit does not start Dehumidifier does not dry the air as it should The unit makes a loud noise when operating Frost appears on the coils Water on floor What to check -Make sure the dehumidifier s plug is pushed completely into the outlet. -Check the house fuse/circuit breaker box. -Dehumidifier has reached its preset level or bucket is full. -Bucket is not in the proper position.
Sociable Remark When using this dehumidifier in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
CD030IU-DPXB 16120100000145
说明书纸张规格:210*143 材质:彩色铜版纸105g.