Specifications

Electrical Installation Instructions
10
10
ARCTIC SPAS
®
MUST BE WIRED IN ACCORDANCE WITH ALL
APPLICABLE LOCAL ELECTRICAL CODES. ALL ELECTRICAL WORK
SHOULD BE DONE BY AN EXPERIENCED, LICENSED ELECTRICIAN
AND APPROVED BY A LOCAL BUILDING / ELECTRICAL INSPECTION
AUTHORITY. WE RECOMMEND THE USE OF APPROPRIATE ELEC-
TRICAL CONDUIT, FITTINGS AND WIRE FOR ALL CIRCUITS. The spa
can be wired with one 32 amp 230 volt single circuit, two 16 amp circuits or
three 16 amp circuits (three phase).
We recommend an electrical subpanel containing appropriate RCD breaker is used to supply power
and protect the spa. The grounding conductor must be at least the same gauge as the line conduc-
tors, but not less than 6 mm
2
. A minimum 6 mm
2
solid copper bond wire is also required. Mount the
subpanel in the vicinity of the spa, but not closer than 1.5m away, in accordance with all local codes. A
qualified electrician must install the electrical circuit.
1. This hot tub must be permanently connected (hard-wired) to the power supply. No plug-in
connections or extension cords are to be used in conjunction with the operation of this hot tub.
Supplying power to the hot tub, which is not in accordance with these instructions, will void both
the independent testing agency listing and the manufacturers warranty.
2. The power supplied to this hot tub must be a dedicated circuit with no other appliances or lights
sharing the power provided by the circuit.
3. Do not use aluminum wire.
4. The appliance should be supplied through a residual Current device (RDC) with a rated tripping
current not exceeding 30mA.
5. To gain access to the hot tubs power terminal block, remove the four screws securing the two
cabinet panels on the side of the spa containing the ETL label. Then open the door to the control
box. (See diagram on previous page).
6. IMPORTANT To maintain TUV Ratings, A water resistant strain relief (rated IPx5 or better) must
be used on the Power Supply Cable where it enters the pack. We recommend Heyco Liquid Tight
Straight Through Fittings.
Note: For cables 12.4mm through 20mm Part # M4346
For cables 15.0mm through 25.4mm Part # M4348
7. Connect wires, color to color, on terminal blocks TB1. TIGHTEN SECURELY! All wires must be
hooked up or damage could result.
8. Close the control box door and reinstall the cabinet side panels.