Specifications
Electrical Specifications
9
9
WARNING!
All electrical hookups must be performed by a licensed electrician!
Power Input
All Arctic Spas
®
are tested for the following:
230 VAC, 50 Hz, 32 A (International)
Connect the power input wires to the terminal block labeled “AC-Input”. Make sure to
respect the alignment and that the screws are properly tightened.
DANGER!
Shock Hazard.
DO NOT PROCEED if
you are not a licensed
electrician. This
diagram is for
reference only!
Warning!
This product must always
be connected to a circuit
protected by a residual
current device.
Proper wiring of the electrical
service box, RCD and in.xm
terminal block is essential!
Check your electrical code
for local regulations. Only
copper wire should be used,
never aluminum.
To install the wiring for the
in.xm spa control, you'll
need a Phillips screwdriver,
Connect the bonding
conductor to the bonding lug
on the left side of the in.xm
spa pack
(a grounded electrode
conductor shall be used
to connect the equipment
grounding conductors).
Grounding
lug
a14 mm nut driver or a at
screwdriver.
Loosen the 2 screws of the
spa pack door and open it.
Remove 20 cm of cable
insulation. Strip away 2.5 cm
of each wire insulation. Pull
the cable through the cutout
of the box and secure it with a
strain relief (trade size 2.5 cm
strain relief; hole diameter:
3.4 cm). Make sure that
only the uncut sheathing is
clamped at this opening. Push
the color-coded wires into
the terminals as indicated on
the sticker and use the 14 mm
wrench or at screwdriver
to tighten the bolts on the
terminals.
After making sure wire
connec-tions are secure, push
them back into the box and
close the door. Tighten the 2
screws of the spa pack door.
Electrical wiring