Specifications

on when the system is put on standby The filter cycle, the Smart Winter mode (see pg 19) and
the heater cant start during this time. All keys are disabled except the On/Off key. A second
long press (5 seconds) will restart the system before the 30 minutes ends.
When power is first applied to the spa, it is “On” by default.
Starting the Blower (Optional):
Press the Blower key to turn Blower on. A second press will turn Blower
off. The built in timer automatically turns Blower off after 20 minutes, unless
it has been manually deactivated.
The “Blower” indicator lights up when Therapy air is on.
Turning the Lights ON:
Press the Light button to toggle the light(s) on and off. If the lights are left on, they
will automatically turn off after 2 hours, unless it has been manually deactivated.
If the spa is equipped with Northern Lights™, or Northern Lights™ Deluxe, the
different lighting sequences can be cycled by pressing the light key on and off repeatedly.
The “Light” indicator is displayed when the light is on.
Programming the Filter Cycle Duration:
The system will automatically perform four one-hour filtration cycles per day.
During a filter cycle:
* Pump 2, Pump 3 (on 3 pump systems) and Blower runs for 1 minute, then
* Pump 1 runs at low speed for the programmed number of hours (see below), and
* The Ozonator is turned on.
To Set the Filter Cycle Duration:
Press the Filter key. The display will
show Fd XX with XX representing currently set filter
cycle duration in hours.