Specifications
17
17
Use the Up & Down arrow keys to change
settings (from 0 to 2).
00 = no filtration
01 = 1 hour/cycle
02 = 2 hour/cycle
When the desired setting is displayed, press
Filter again. The display will show FFxx,
with “xx” representing the filter cycle
frequency per day.
Use Up or Down arrow keys to change
setting (from 1-4). When the desired
setting is displayed, press Filter to confirm.
A filter cycle will start immediately. The
“Filter Cycle” indicator lights up when a
filter cycle is on.
F 02
p
FF02
A flashing “Filter Cycle” indicator means that the system has stopped filtering be-
cause water temperature is 2ºF (1ºC) above the Set Point. If the temperature cools
down before the scheduled end of the cycle, filtering will resume for the rest of the
programmed duration. After a power failure, the first filter cycle will start 12 hours
after power has been restored.
Overtemp During Filter Cycle
In order to prevent excessive water temperatures due to long Filter cycles during warm weather, the
system has a special safeguard.
If the water temperature exceeds the set point by more then 2
o
F (1
o
C), the system will cancel the
Filter cycle and the Filter cycle icon will blink for the remainder of the filter cycle. The Filter cycle
icon blink pattern will be: ON for 1/2 second, OFF for 1/2 second, ON for 1/2 second, then fi-
nally OFF for 1 1/2 seconds. This sequence will then repeat. The filtration cycle will automatically
reset itself once the water temperature falls below the set point.
FF04