Technical data
18
Onzen Technical Guide
Is Sanitizer Being Produced and Delivered to Spa Water?
is test requires:
· e water temperature to be at least 80º F (27º C).
· e Filter Cycle Duration to be set to 00.
· Onzen Cycle Duration programmed to On 24. Onzen system will run for 24 hours per day.
Step 1. Set Filtration Cycle Time to Fd 00 (= No Filtration)
Press the Filter Cycle Key until SE is displayed.
e Filter Cycle Duration details “Fd” will be displayed “Fd XX” .
Use down arrow key to change the Filter Cycle
Duration to Fd 00.
is de-activates the ltration pump so you can see the mist of
gas bubbles produced by the Onzen System.
Step 2. Scroll to On (Onzen Duration) Seing
Scroll through the seings by pressing the Filter Cycle
key until it reads “On X ”. (“x” will be a value between
0 & 24).
Step 3. Change On Seing to On 24
Change On seing to On 24.
On 24 programs the Onzen system to produce sanitizer 24 hours daily.
Step 4. Scroll rough Seings
Continue scrolling through the seings by repeatedly pushing the
Filter Cycle key until the pack resets.
5
5
5