Is Sanitizer Being Produced and Delivered to Spa Water?
is test requires:
· e water temperature to be at least 80º F (27º C).
· e Filter Cycle Duration to be set to 00.
· Onzen Cycle Duration programmed to On 24. Onzen system will run for 24 hours per day.
Step 1. Set Filtration Cycle Time to Fd 00 (= No Filtration)
Press the Filter Cycle Key until SE is displayed.
e Filter Cycle Duration details “Fd” will be displayed “Fd XX” .
Use down arrow key to change the Filter Cycle
Duration to Fd 00.
is de-activates the ltration pump so you can see the mist of
gas bubbles produced by the Onzen System.
Step 2. Scroll to On (Onzen Duration) Seing
Scroll through the seings by pressing the Filter Cycle
key until it reads “On X ”. (“x” will be a value between
0 & 24).
Step 3. Change On Seing to On 24
Change On seing to On 24.
On 24 programs the Onzen system to produce sanitizer 24 hours daily.
Step 4. Scroll rough Seings
Continue scrolling through the seings by repeatedly pushing the
Filter Cycle key until the pack resets.