Technical data

6
Onzen Technical Guide
1.9 W C A/A & L
ABBREVIATION/ACRONYMS DEFINITION CORRECT CHEMICAL LEVELS
CH Calcium Hardness 50 - 150 ppm
TA Total Alkalinity 80-100 ppm
pH Potential Hydrogen 7.2 – 7.6 ppm
FCL Free Chlorine 1 – 3 ppm
ORP Oxidation–Reduction Potential 600 - 1000
1.10 S A A
ABBREVIATION/
ACRONYMS
DEFINITION
Fd
Filter Cycle Duration
Fd 00 = no ltration.
Fd 01 = 1 hour/cycle.
Fd 02 = 2 hour/cycle.
FF
Filter Cycle Frequency
FF 1 = 1 cycle in 24 hours.
FF 2 = 2 cycles in 24 hours.
FF 3 = 3 cycles in 24 hours.
FF 4 = 4 cycles in 24 hours.
On
Onzen Cycle Duration
0-24 Hours per day
* Cycles are divided into 4
ie: If 8 hours is selected, the system will perform 4 x 2 hour cycles per day.
O3
Ozone Cycle Duration
0-24 hours per day
* Peak II only, if Peak 1 is installed ozone will run during ltration.