Instruction manual

Model HF65R                       7 
WATER HEATING COIL (MODEL SHW4) 
ARDENT ENERGY heating units are designed to heat your do-
mestic hot water during the heating season. 
The HF65 can accept one or two coils (1 per side). The coil re-
places all but one of the firebrick on the side located. 
Procedure
: 
NOTE:  Ensure installation complies with local 
plumbing codes. 
1. Remove both side shrouds by unscrewing 4 or 6 
screws at back 
2. Remove rear heat shield and hammer out the 2 
knockouts on the side desired. (see Fig 5) 
3. Loosen cross draft angle nuts on side of unit. (2 
each side located on outside of firebox). 
4. Remove brick from that side. 
5. Punch out 2 knockouts at back of stove. Reach in 
through punched out holes with a bar extension 
and punch out knockouts in primary heat ex-
changer. Knock outs are out of necessity tight. A 
sharp blow with a heavy hammer will be required. 
6. Position water coil in stove, replace brick and 
tighten cross draft angle nuts on side of heater to 
hold coil in place. 
7. Install mineral wool gasket and plate on outside 
and screw tight. 
8. Replace shrouds and heat shield. 
TANK CONNECTION
It is recommended that the ‘2 tank” system be used. The first 
tank or “Range Boiler” must remain un-insulated to dissipate any 
excess heat generated by the hot water coil. 
Connection of piping to Range Boiler must be strictly followed as 
shown in the Diagram. The 2 shut—off valves must be no smaller 
than 3/4 inch GATE valves. Make certain that the PRV (Watts 3L) 
and P&TRV (Watts 100XL) are installed in their respective loca-
tions and not vice versa. Maximum pressure setting is 150 psi. 
Do not use less than 3/4 inch diameter standard pipe between 
range boiler and heater, orientation of pipe must be slightly uphill
from the coil outlet to the upper connection at the tank, otherwise 
vapor lock will occur and water will not circulate. Min. Range 
Boiler recommended is 30 Imperial gallon capacity. 
FIG. 6 
REPLACEMENT PARTS LIST 
ITEM  QTY  DESCRIPTION  PART # 
1  1  Closer pawl  6261 
2  1  Hug lock nut  1442 
3  1  Scandinavian baffle  AP014 
4  1  Bypass damper  A237R4 
5  2  Fin  AP038 
6  2  Outside fin  A407R4 
7  28”  Ball chain  6110 
7-A  2  Chain pendant  6121 
8  1  Flame deflector  A533R1 
9  1  Down draft baffle  A532R3 
10  2  Cross draft angle  A217R8 
11  1  Air inlet assembly  6411 
12  1  Primary air heat exchange assembly  A900R0 
13  14  Firebrick 1 1/4 x 4 1/2 x 9  7101 
14  1  Door sill  A259R2 
15  2  Door hinge  6260 
16  60”  Door gasket 5/8 dia. glass rope  7006 
17  1  Door liner  A302R1 
18  1  Door assembly  A317R3 
19  1  Door handle 3/8 ID  6010 
20  1  Door closer assembly  6201-1 
21  1  Door closer catch  A280R1 
22  2  Control handle 5/16 ID  6005 
23  1  Bypass bar  A264R10 
24  1  Draft control rod assembly  A168R15 
25  1  Bypass lever  A239R10 