User Manual

ArecontVisionSurroundVideo
®
OmniInstallationManual
Page | 13 support@arecontvision.com
SurroundVideo®Omni
DigitalInputandOutput
Use4positionconnectorinsidecamerahousingtointerfacewithDigitalI/O.
DIGITALI/O
BLACKIN‐
WHITEIN+
YELLOWOUT‐
ORANGEOUT+

ElectricalCharacteristics
MIN MAX
InputVoltage(V)
(Measuredbetween+
andterminals)
ON 2.9 6.3
OFF 0 1.3
OutputCurrent(mA)
(Measuredbetween+
andterminals)
AppliedVoltageRange:
080V
ON‐ 50
OFF‐ 0.1
NOTE:Boththeinputandtheoutputareelectricallyisolatedfromtherestofthecamera’selectrical
circuitryviageneralpurposephotocouplers.Theinputisadditionallyprotectedwithaserial250Ohm
resistorandadebouncingcircuit.Durationofanyinputsignalshouldbeatleast5mstocomplywiththe
requirementsofthedebouncingcircuit.