SurroundVideo®Omni
DigitalInputandOutput
Use4positionconnectorinsidecamerahousingtointerfacewithDigitalI/O.
DIGITALI/O
BLACKIN‐
WHITEIN+
YELLOWOUT‐
ORANGEOUT+
ElectricalCharacteristics
MIN MAX
InputVoltage(V)
(Measuredbetween+
and–terminals)
ON 2.9 6.3
OFF 0 1.3
OutputCurrent(mA)
(Measuredbetween+
and–terminals)
AppliedVoltageRange:
0‐80V
ON‐ 50
OFF‐ 0.1
NOTE:Boththeinputandtheoutputareelectricallyisolatedfromtherestofthecamera’selectrical
circuitryviageneral‐purposephotocouplers.Theinputisadditionallyprotectedwithaserial250Ohm
resistorandadebouncingcircuit.Durationofanyinputsignalshouldbeatleast5mstocomplywiththe
requirementsofthedebouncingcircuit.