Installation Manual

Installation Manual
Page | 30 support@arecontvision.com
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com avsales@arecontvision.com
SurroundVideo® Omni G3
OPTION-2: INPUT VOLTAGE DETECTION
In this scheme the IN- & GND terminals can be tied to an external power source. The camera can
detect a range of voltage to trigger an internal alarm on|off condition.
Figure 6
The following table shows the input voltage range and electrical characteristics:
Input Voltage Detection
Terminals
External
Status
Camera
Status
Voltage
Range
Current
Range
IN- &
GND OFF ON 0-1V 0-2mA
ON OFF 2-12V 10-50mA
The status of the camera can be read with the following command:
http://camera_ip/get?auxin