Arecont Vision MegaViewTM v1 Installation Manual 0|P a g e
Arecont Vision MegaViewTM v1 Installation Manual MegaView TM v1 Installation Manual Inside the box: A. B. C. D. TM Arecont Vision MegaView v1 Pack of four (4) wood screws and four (4) dry wall anchors Security L-key Mounting Template Mounting the Camera: 1. Remove camera and hardware from the box. TM NOTE : MegaView v1 is available in two versions, DN and IR, shown in image 2. Both versions have motorized day night switcher but only IR version supports an IR LED ring.
Arecont Vision MegaViewTM v1 Installation Manual Image 3 CAUTION: Only adjust the screws with an arrow pointing to them on the bracket base and camera body (Image 4) 4. Align the holes in the camera with the prepared holes on the mounting surface. Attach the camera to the mounting surface with the wood screws or any other hardware that fits the mounting application. (image 6) NOTE: Use junction box adapter, SV-JBA, to ensure a water tight installation as shown in Page 5.
Arecont Vision MegaViewTM v1 Installation Manual Optional: Connecting External Power for Camera, IR Illuminator and Fan. 6. To use the external power, 12-48VDC or 24VAC, to power on camera, IR illuminator and fan, connect external power with pigtail cable connector (Image 7) NOTE: Both the input and the output are electrically isolated from the rest of the camera’s electrical circuitry via general-purpose photo couplers.
Arecont Vision MegaViewTM v1 Installation Manual Replacing the IR LED board: 9. Unscrew glass ring (Image 9) 10. Use Phillips screwdriver to remove IR LED board (Image 10) 11. To replace IR LED board, unplug cable and replace new IR LED board (Image 11) TM NOTE: Only MegaView v1 IR version can accommodate a replacement IR LED board. IR LED Board cannot be added to DN version.
Arecont Vision MegaViewTM v1 Installation Manual Important Note Correct installation for outdoor application of MegaView™ v1 Correct Installation: Incorrect Installation: Please install the MegaView™ v1 with junction box adapter (SV-JBA) to avoid risk of water leakage in outdoor applications as shown in Image 12. Attaching the MegaView™ v1 directly onto a wall surface may result in water leakage, see Image 13.
Arecont Vision MegaViewTM v1 Installation Manual MegaView™v1 Junction Box Adapter (SV-JBA) Installation Instruction Inside the box: A. B. C. D. E. hardware suitable for the mounting surface.
Arecont Vision MegaViewTM v1 Installation Manual MegaView™v1 Electrical Box Adapter (SV-EBA) Installation Instructions Inside the box: A. B. Electrical Box Adapter Pack of four (4) machine screws Image 18-1 Single gang box MegaView™ v1 Bracket holes A Image 18-2 Double gang box Image 17 Not included but needed: • • #2 Phillips head screw driver Common Electrical Box, such as single gang box, double gang box, or square electrical boxes shown in Image 18-1~4.
Arecont Vision MegaViewTM v1 Installation Manual MegaView™v1 Pole Mount Adapter (MD-PMA) Installation Instructions Inside the box: A. B. C. D. E. Pole Mount Adapter 2x Compression Fittings 2x Small Steel Straps 2x Large Steel Straps Pack of four (4) machine screws 3. Use the supplied two Steel Straps to attach the Pole Mount Adapter to the pole and tighten the compression screws as shown in Image 21. 4. To adjust MegaView™v1 bracket, please reference “Mounting the Camera”, if needed.
Arecont Vision MegaViewTM v1 Installation Manual MegaView™v1 Corner Mount Adapter (MD-CRMA) Installation Instructions Inside the box: A. B. C. D. 3. Corner Mount Adapter 2x Compression Fittings Pack of four (4) machine screws 2x Packs of four (4) wood screws and four (4) dry wall anchors Using the screws provided (or other hardware) to attach the Corner Mount Adapter to an exterior 90° corner wall as shown in Image 22. 4. To adjust MegaView™ bracket, please reference “Mounting the Camera”, if needed.
Arecont Vision MegaViewTM v1 Installation Manual 9|P a g e