Arecont Vision MegaDome® 2 Installation Manual (DN Models Only) ® MegaDome 2 Installation Manual (DN Models Only) Inside the box: Mounting the Camera: ® Arecont Vision MegaDome 2 camera (DN Models only) B. Mounting template C. CD with AV100 software and user manuals (License Key Required for Recording) D. AC & DC power cable E. I/O cable F. Pack of four (4) wood screws and four (4) dry wall anchors G. Security L-Key H. One double-sided hex key I. One single-sided hex key J. Magnetic core A.
Arecont Vision MegaDome® 2 Installation Manual 4. NOTE: Make sure that your installation of wires complies with Electrical Code of the local government where the camera is installed and that no bare wires are exposed. If you are using the side conduit opening, remove the conduit plug by first removing the socket set screw using the provided double-sided hex key (Image 3).
Arecont Vision MegaDome® 2 Installation Manual Adjusting the Tilt, Pan, Z-Axis (yaw) and Focus: 9. To adjust the tilt, use a #1 Phillips screwdriver to loosen the screw on the side of the plastic lens bracket 1/4 turn (Image 5). CAUTION: Do not remove the screw! 10. Adjust lens tilt as required and tighten the screw. 11. To adjust the pan, use a #2 Phillips screwdriver to loosen the screw as shown in Image 5. Z-Axis (Yaw) Tilt Pan CAUTION: Do not remove the screw. 12.
Arecont Vision MegaDome® 2 Installation Manual Camera Installation: 18. Install the AV100 application manager Software as shown in Image 7 (found on the CD). NOTE 2: Advanced Mode: software will automatically discover but allow manual update of the IP address. See “AV100 Installation Manual” (found on the CD) for details on Advanced Mode. 19. Run the AV100 application manager by double clicking on the icon as shown in Image 8 (found on your desktop). Image 7 Image 8 20.
Arecont Vision MegaDome® 2 Installation Manual Camera Web Page User Manual” (found on the CD) for details on the web interface. Image 11 25. When all cameras appear, select “Save/Exit.” The AV100 application will appear. 26. From the “AV100 Application Manager” menu, select “Run” to view live images. NOTE: See the “AV100 Installation Manual” (found on CD) for details on camera configurations.
Arecont Vision MegaDome® 2 Installation Manual Important Note How to correctly install MegaDome® 2 on a ROUGH surface wall Correct Installation: Please install the MegaDome® 2 with wall mount, (MD-WMT2) and junction box adapter (SV-JBA) to avoid water leakage risk on ROUGH surface wall surface as shown in Image 15.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Wall Mount (MD-WMT2) Installation Instructions Caution: MD-WMT2 only fits with SV-JBA and SV-EBA but not with the older MD-JBA and MD-EBA! Inside the box: A. B. C. D. E. F. Wall mount Top shield Mounting template One double-sided hex key Pack of four (4) machine screws Pack of four (4) wood screws and four (4) dry wall anchors Image 18 2. Using the mounting template, prepare the mounting surface. 3.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Junction Box Adapter (SV-JBA) for MD-WMT2 Installation Instruction Caution: SV-JBA should always be used in conjunction with a wall mount, MD-WMT2, for outdoor installation. SV-JBA will only fit with the MD-WMT2 wall mount. It does not fit the camera dome or older wall mount MD-CMT! Inside the box: A. B. C. D. E.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Pendant Mount (MD-CMT) Installation Instructions Inside the box: A. B. C. D. E. F. Top shield Pendant Mount Mounting template Pack of four (4) small machine screws Pack of four (4) machine screws Pack of four (4) wood screws and four (4) dry wall anchors G. One double-sided hex key H. Small square rubber gasket I. Large round rubber gasket Image 22 Not included but needed: J. 2.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Wall Mount Cap (MD-CAP) Installation Instructions Inside the box: A. B. Wall Mount Cap (MD-CAP) Pack of four (4) machine screws MD-CAP Not included but needed: • • • • 1½” NPT pipe nipple 1½” NPT coupling 1½” NPT flange #2 Phillips head screwdriver 1 ½” Coupling 1 ½” Pipe 1 ½” Flange A B Image 25 3. Run the Ethernet cable and outside power cable (if necessary) through the pendant. Image 24 1.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Flush Mount Adapter (MD-FMA) Installation Instructions Inside the box: A. white trim ring B. Flush mount adapter C. Mounting template D. Pack of four (4) machine screws and one (1) eyelet 5. Tighten the “lever screws” until the flush mount adapter is snuggly installed, as shown in Image 27. The “Support Arm” will ride down the screw to compress the mounting surface. NOTE: Do not over-torque the lever screws. 6.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Electrical Box Adapter (SV-EBA) Installation Instructions Caution: 3. Attach electrical box adapter to electrical box. SV-EBA fits with MD-WMT2 but not fit with ® MegaDome 2 and MD-CMT! Inside the box: (Accessory Sold Separately) A. B.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Pole Mount Adapter (MD-PMA) Installation Instructions Inside the box: A. Pole mount adapter B. 2x compression fittings C. 2x small steel straps D. 2x large steel straps E. Pack of four (4) machine screws 4. Run the Ethernet cable and outside power cable (if necessary) through the compression ® fittings and MegaDome wall mount, MDWMT2. 5.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 Accessory (Sold Separately) Corner Mount Adapter (MD-CRMA) Installation Instructions Inside the box: A. B. C. D. Corner mount adapter 2x compression fittings Pack of four (4) machine screws 2x Packs of four (4) wood screws and four (4) dry wall anchors 3. Attach wall mount adapter to corner mount adapter and attach the wall mount cap as shown in Image 36.
Arecont Vision MegaDome® 2 Installation Manual Heater Kit MD2-HK Installation Instructions (Accessory Sold Separately, except –H Models) Note: Heater kit MD2-HK is not available on ® MegaDome 2 WDR models! 3. With the heater element facing away from the main board in the camera, align the two (2) holes on the heater board with the two holes on gimbal base shown in Image 38. 4. Attach the heater board with the standoff on gimbal base as shown in Image 39. Inside the box: A. B. C.
Arecont Vision MegaDome® 2 Installation Manual ® MegaDome 2 I/O Cable Connection Inside the box: A. I/O Cable A I/O Connector Image 40 Not included but needed: • 1. Image 41 Flat head screwdriver ® To use the I/O ports of the MegaDome , run the I/O cable through the hole in the bottom of the camera and plug it into the connector as shown in Image 41. NOTE: The connection is a little stiff so be sure to apply enough pressure to connect it; using a flat head screw driver to push it in is recommended.