1.2. Problems in the temperature sensor module
The receiver receives signals from sensors, but fails to registrate
signals from one sensor in particular.
Potential problems:
- Batteries are missing or are at a low charging level
- Reversed polarity of the sensor’s batteries
- The sensor’s location is outside of the receiver’s reception
range
- Damage to the sensor (by corroded battery contacts, moisture
or battery leakage)
- Problems in the radio signal communication
Suggested solutions:
- Insert fully charged batteries in the sensor and repeat the
communication test (please check the polarisation of the
batteries before inserting!!)
- Check the battery contacts and remove all corrosion and
moisture effects.
Technical details
Type: BS750-SD
Radio: ISM 433MHz, Multilogger RF-protocol.
USB: USB 2.0, Multilogger USB-protocol.
Supply: – 7.5V DC / 100mA
RTC battery: CR2032 3V
SD card: micro SD (SD, SDHC)
Internal memory: 2MB data-ash (about 9 days for
10 sensors, 18 days for 5 sensors, etc.)
Software: http://www.arexx.com
Extra information and possible updates can be found on www.arexx.com