Specifications
What is an example for a rule?
($v< 0 || $v> 9) && $i==11867
How to transfer a rule into the BS-500 or BS-1000 receiver?
The BS-510 will only work with the pc software and does not allow the
uploading of rule files. In this case rules will be defined within the
messenger software. The BS-1000/TL-09 may be working independently
from the pc software. These modules allow you to upload a rule file, which
may be organized in several ways:
BS-1000 via the network:
- using the embedded webserver: visit the “rules”-page in the section
'administrative pages'.
- using the rule editor: menu Extra->'Upload current file to bs1000'.
Via USB:
- using the ConfigFileUpload tool: via USB you may upload rule files and
other configuration files to the station.
The BS-1000 cannot be accessed by the network?
Check the network connection; has the network connector correctly been
plugged? Check the network by connecting a laptop to the plug.
Connect the USB and a network cable. Use the Networkconfig-tool in the tool
menu at the logger software. With the help of this tool you will find the
current IP-address for the BS-1000.
Check the DHCP server if this is being used.
Use the internet browser to contact the BS-1000. Apply the IP address you
did find with the help of the Networkconfig-tool.
Check whether the BS-1000 works by USB port.
Check the blinking of the LED next to the network connector at the BS-1000.
Flash the most recent firmware in de BS-1000 (download via
www.arexx.com/templogger)
Check the firewall.
Ask your network administrator for help.
Why am I unable to login to the BS-1000 as an admin?