EG OPERATING INSTRUCTIONS • ISTRUZIONI D’USO NOTICE D’UTILISATION • BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO • MANUAL DE INSTRUÇÕES ΟΔΗΛΙΕΣ XPHΣΕΩΣ ADIBS13DC ADICS13DC I F D E P GR Split air conditioner system • Condizionatore d’aria split system Climatiseurs split • Split-klimagerät Acondicionador de aire de consola partida sistema split • Aparelho de ar condicionado-Sistema Split DIAIROUMENES MONADES KLIMASMOU 37.4254.071.
contents EG NAME OF PARTS AND OPERATION SELECTOR SWITCH 3 INSTALLATION LOCATION 4 ELECTRICAL REQUIREMENTS 4 SAFETY INSTRUCTIONS 4 USING THE REMOTE CONTROL UNIT 4 REMOTE CONTROL UNIT 5 HOW TO SET THE PRESENT TIME 6 COOLING 6 HEATING 6 AUTOMATIC OPERATION 6 DEHUMIDIFYING (DRY) 7 FAN ONLY 7 ADJUSTING THE FAN SPEED 7 NIGHT MODE/ENERGY SAVING 7 HIGH POWER MODE 7 SETTING THE TIMER 8 SETTING THE 1 HOUR TIMER 8 SETTING THE HOLIDAY TIMER 8 OPERATION WITHOUT THE REMOTE CONTROL UNI
NAME OF PARTS AND OPERATION SELECTOR switch EG 3 11 4 10 5 1 6 7 8 9 OFF LAMPS FUNTION 1. Remote control unit. 2. Remote control sensor: Detects the room temperature around the remote control unit, the air conditioner is controlled accordingly. 3. Air outlet: Conditioned air is blown out of the air conditioner through the air outlet. 4. Air intake: Air from the room is drawn into this section and passes through air filter which removes dust. 5.
INSTALLATION LOCATION l EG l l l l USING THE REMOTE CONTROL UNIT HOW TO INSTALL BATTERIES l Remove trhe lid in the rear part of the remote control unit and check the settings of the four microswitches as shown below: PLEASE, SEE THE END We recommend this air conditioner to be installed properly by qualified installation technicians in accordance with the installation instructions provided with the unit.
REMOTE CONTROL UNIT DISPLAY Information is displayed when the remote controller is switched on.
HOW TO SET THE PRESENT TIME DEFROSTING OF OUTDOOR UNIT HEAT EXCHANGER 1. Press the button ST three times. The time indication alone flashes. 2. Press the H button until the present time hour is displayed. Press the M button until the present time minutes are displayed. The display will automatically stop flashing. EG When the outdoor temperature is low, frost or ice may appear on the heat exchanger coil, reducing the heating performance.
A U TO M A T I C O P E R A T I ON I N M U L T I S P L I T CONFIGURATION When the air conditioning system configuration is multisplit and there is more than one indoor unit connected, the automatic mode operates as follows: - the first unit that switches on the system also decides the operation mode (cooling or heating) for all the other units that will be switched on after the first one; - when the system has been switched on in cooling mode and one unit is activated in heating mode, an error will be signal
SETTING THE TIMER EG SETTING THE 1 HOUR TIMER A) HOW TO SET THE ON TIME 1. Press the ST button once. The ON and time indications flash. 2. Press the H button until the designed hour is displayed. Press the M button until the designed minutes are displayed. The display will change automatically back to show the present time after 10 sec. 3. Press the ON/OFF button to start the air conditioner. 4. Press the button to activate the ON timer. B) HOW TO SET THE OFF TIME 1. Press the ST button twice.
AIR filter OPERATION WITHOUT THE REMOTE CONTROL UNIT The air filter should be cleaned at least once every six months or more frequently; it depends on the real operation conditions. If you have lost the remote control unit or it has troubles, follow the steps below. 1. When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode (COOL or HEAT). 1. EG NOTE The air conditioner will start in HIGH fan speed.
Trouble: the air conditioner does not run at all. Possible cause: 1. Power failure. 2. Leakage breaker tripped. 3. Operation button is OFF. 4. Batteries in remote control unit have run down. Remedy: 1. Restore power. 2. Contact service centre. 3. Press the button again. 4. Replace batteries. TIPS FOR ENERGY SAVING DO NOT: l Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. l Let direct sunlight into the room.
O = LED OFF l = LED ON F O E1 E2 l OPERATION E0 ERROR O F F STANDBY F = Flashing LED O O F LEDS TIMER AUTO-DIAGNOSIS TABLE SYSTEM BEHAVIOUR SOLUTION Fan is stopped and flap is closed. Check the error code using the approThe system restarts automatically priate LEDs on the PCB of the outdoor as soon as the problem on the out- unit. door unit is solved. Follow the indications of the diagnosis for the outdoor unit.
O = LED OFF E3 ERROR l = LED ON F OPERATION F STANDBY F = Flashing LED F LEDS TIMER SYSTEM BEHAVIOUR Communication error between the Fan is stopped and flap is closed outdoor unit and the indoor unit after 30 seconds of missing communication. The system restarts automatically as soon as the communication is recovered. POSSIBLE CAUSE Check that the fan motor is not damaged and it doesn’t create short circuit on the indoor PCB.
= LED ON O F F O STANDBY F = Flashing LED F F O F LEDS TIMER SYSTEM BEHAVIOUR SOLUTION Check that the fan motor is not damaged and, if necessary, replace it. Check that the fan motor is not locked. Fan is stopped and flap is closed. Check that the fan motor is properly The system restarts automatically connected to the PCB as shown in the after some seconds. electrical wiring diagram. Check that none of the indoor units of the system has a communication error.
EXPLANATION AND USE OF THE REMOTE CONTROL UNIT’S MICROSWITCHES EG Switch 1 and 2: These switches are used to match the remote control with the specific internal units. Switch 3 and 4: these switches have been provided for future use; they have no function today. Keep them in OFF position. Switch 5 and 6: these switches set the remote control in WIRELESS or WIRED mode. Default position is ON (WIRELESS mode). For WIRED control, remove the batteries and set in OFF position.
Via Varese, 90 - 21013 Gallarate - Va - Italy Tel. +39 0331 755111 - Fax +39 0331 776240 www.argoclima.